HEGINS, PA —
OSHA Inspection: MI HOME PRODUCTS INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MI HOME PRODUCTS INCORPORATED in PO BOX 528, PARK LANE, HEGINS, PA 17938 (NAICS 332321). OSHA activity number 305254864.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MI HOME PRODUCTS INCORPORATED
- Site address
- PO BOX 528, PARK LANE
- City
- HEGINS
- State
- PA
- ZIP
- 17938
- Mailing
- PO BOX 528, HEGINS, PA 17938
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- SIC code (legacy)
- 3442
- Employees
- 150
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- May 19, 2004
- Abate by
- Jul 7, 2004
- Penalty
- Initial $1,500 · Current $975 Reduced
Recent events (2)
- — I (S) $975.00
- — Z (S) $1500.00
5(a)(1)
- Issued
- May 19, 2004
- Abate by
- Dec 7, 2004
- Penalty
- Initial $1,500 · Current $975 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which are free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an explosion hazard because the air material separator, which did not have deflagration vents, and dust bags of the dust collection system were located inside of the building. a.)MI Home Products, Inc. - The ductwork for the conveyor, which was inside the building, did not have chokes or other devices to prevent the spread of an explosion in the ducts. Abatement Note: One feasible and useful abatement method is to locate air-material serparators outside of the building in accordance aith NFPA 654, Section 3.13 Air-Material Separators (Air-Separation Devices), or meet the exceptions of that section. (Exception No. 2 states: Those air-material separators that are located within 20 ft. (6 m) of an exterior wall and are equipped with deflagration vents that are vented through ducts to the outside and where the reduced venting efficiency due to the duct has been accounted for. The ducts shall be designed to withstand the effects of the deflagration. Exception No. 3 states: The requirements of this section shall be permitted to be omitted if the volume of the air-material serparator is less than 8 cu. ft. (0.2 m 3)). ABATEMENT CERTIFICATION REQUIREDATION
Recent events (3)
- — P (S) $975.00
- — I (S) $975.00
- — Z (S) $1500.00
1910.178 M05 I
- Issued
- May 19, 2004
- Abate by
- May 24, 2004
1910.169 B03 II
- Issued
- May 19, 2004
- Abate by
- Jul 7, 2004
More inspections at MI Home Products Incorporated
View MI Home Products Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305254864.