Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LEMBERG ELECTRIC CO., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LEMBERG ELECTRIC CO., INC. in 209 E. MASON ST., MILWAUKEE, WI 53202 (NAICS 000000). OSHA activity number 305273062.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lemberg Electric CO., INC. — free Get an email when a new federal OSHA severe-injury report for Lemberg Electric CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
209 E. MASON ST.
City
MILWAUKEE
State
WI
ZIP
53202
Mailing
730 N 109TH ST. P.O.BOX 13527, WAUWATOSA, WI 53213
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1731
Employees
122
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Oct 10, 2002
Abate by
Oct 16, 2002
Penalty
Initial $3,500 · Current $2,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that:
(a)On or about September 19, 2002, at the jobsite, located in the
parking garage at 209 E. Mason Street, Milwaukee, WI, an
employee (electrician), engaged in the installation of electrical
lighting upgrades, on the sloped (10 to 15 degrees) driveway ramp
to the basement parking lot and while elevated 3 feet and
traversing the sloped driveway in reverse, in a Skyjack SJIII
Model 3015, Compact, Battery-Operated, Self-Propelled Mobile
Elevating Work Platform, (Scissor Lift), the scissor lift tipped over
injuring both of the employee's arms.
Among others, one acceptable method of abatement would be to
follow procedures specified in the ANSI/SIA A92.6-1999, for Self-
Propelled Elevating Work Platforms, specifically those identified
in sections 4.6.6 Slope Warning, 8.6 Before Operation items (1)
through (3), also section 8.7 Workplace Inspection items (1)
through (9) and section 8.10.
No certification required.  Violation Abated.
Recent events (2)
  • — I (O) $2000.00
  • — Z (S) $3500.00

View Lemberg Electric CO., INC.'s full OSHA safety record →