OSHA Inspection: PLAINFIELD BOARD OF EDUCATION - MAINTENANCE DEPT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PLAINFIELD BOARD OF EDUCATION - MAINTENANCE DEPT in 920 PARK AVENUE, PLAINFIELD, NJ 07060 (NAICS 000000). OSHA activity number 305308116.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Plainfield Board of Education - Maintenance Dept — free Get an email when a new federal OSHA severe-injury report for Plainfield Board of Education - Maintenance Dept is published. One employer, no account, unsubscribe in one click.
Site address
920 PARK AVENUE
City
PLAINFIELD
State
NJ
ZIP
07060
Mailing
504 MADISON AVENUE, PLAINFIELD, NJ 07060
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
8299
Employees
16
Ownership type
B

24 citations on file for this inspection.

1910.212 A01

Serious 2 instances 16 exposed
Issued
May 15, 2002
Abate by
Jul 17, 2002

1910.22 A03

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.36 D02

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.37 F06

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.37 K02

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.37 Q01

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.37 Q02

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.38 A01

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.38 B01

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.106 D02 I

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.146 C04

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.147 C01

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.176 B

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.176 C

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.213 C01

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.213 C02

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.213 C03

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.215 A04

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.215 B09

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.219 D01

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.253 B04 III

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.305 A02 I

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

1910.305 J02 II

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002

5(a)(1)

Serious 1 instance 16 exposed
Issued
May 13, 2002
Abate by
Jul 17, 2002
N.J.S.A.  34:6A-33(a):  The employer did not provide the employees with a
place of employment which was free from
recognized hazards.
LOC:  Garage, Overhead Garage Door
There existed a hazard of crushing injury/death when entering/exiting
through the overhead garage door.
Comment:  Some methods of abatement would include (as set forth in ANSI
standard A156.8) and the
following:
1. A constant pressure actuation switch. This would always be operated in
sight
of the door so that it could
be released and manually reversed if an obstruction was hit.
2. Installation of a reversing edge switch. This would allow an automatic
closing control out of sight of the
door, but would immediately reverse the direction of the door upon
striking an obstruction. A
variation to this option would be the use of photoelectric cells that
would reverse the door when an
obstruction was encountered by the beam. OR
3. A three-button control switch. If the following conditions are also
met:
(a) It is provided with a permanent placard adjacent to the switch with
the following warning letters
at least 1/4" high: WARNING TO PREVENT ENTRAPMENT DO NOT START DOOR
DOWNWARD UNLESS DOORWAY IS CLEAR
(b) The control station and placard are located within sight of the
doorway.
(c) Automatic closing controls are not also installed.
(d) Operator must remain at the control station and observe the door until
the door is fully closed.