SOMERS POINT, NJ —
OSHA Inspection: SOMERS POINT SEWER SHOP AND PUMPING STATIONS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SOMERS POINT SEWER SHOP AND PUMPING STATIONS in DEFEO LANE, SOMERS POINT, NJ 08244 (NAICS 000000). OSHA activity number 305308181.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOMERS POINT SEWER SHOP AND PUMPING STATIONS
- Site address
- DEFEO LANE
- City
- SOMERS POINT
- State
- NJ
- ZIP
- 08244
- Mailing
- SOMERS POINT PUBLIC WORKS DEPARTMENT, SOMERS POINT, NJ 08244
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 9199
- Employees
- 2
- Ownership type
- B
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Apr 30, 2002
- Abate by
- Jun 24, 2002
General-duty citation text
29 CFR 1910.5(a)(1): The employer did not provide the employees with a place of employment which was free from a recognized hazard. LOC: a) Sewer Shop, Powered Overhead Door The employees were exposed to a hazard of crushing/death when entering/exiting through the overhead doors. Reference: ANSI-A156.8 Comment: Feasible methods of abatement could include: 1) A constant pressure actuation switch. This would always be operated in sight of the door so that it could be released and manually reversed if an obstruction was hit. 2) Installation of a reversing edge switch. This would allow an automatic closing control out of sight of the door, but would immediately reverse the direction of the door upon striking an obstruction. A variation of this option would be the use of photoelectric cells that would reverse the door when an obstruction was encountered by the beam. 3) A three button control switch. If the following conditions are met: a) It is provided with a permanent placard adjacent to the switch with the following warning letters at 1/4" high. WARNING- TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR. b) The control station and placard are located within sight of the doorway. c) Automatic closing controls are not installed. d) Operator must remain at the control station and observe the door until the door is fully closed.
More inspections at Somers Point Sewer Shop and Pumping Stations
View Somers Point Sewer Shop and Pumping Stations's full OSHA safety record →
More inspections in this industry (NAICS 000000)