SPRINGFIELD, NJ —
OSHA Inspection: SPRINGFIELD DEPARTMENT OF PUBLIC WORKS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SPRINGFIELD DEPARTMENT OF PUBLIC WORKS in 100 MOUNTAIN AVE., SPRINGFIELD, NJ 07081 (NAICS 000000). OSHA activity number 305336836.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPRINGFIELD DEPARTMENT OF PUBLIC WORKS
- Site address
- 100 MOUNTAIN AVE.
- City
- SPRINGFIELD
- State
- NJ
- ZIP
- 07081
- Mailing
- 100 MOUNTAIN AVE, SPRINGFIELD, NJ 07081
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 8299
- Employees
- 20
- Ownership type
- B
Citations
26 citations on file for this inspection.
1910.22 B01
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.38 A01
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.38 B01
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.106 D02 I
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.146 C04
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.147 C01
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.157 E02
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.169 A02 I
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.176 B
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.176 C
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.212 A01
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.212 B
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.213 C01
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.213 C02
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.213 C03
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.215 A04
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.215 B09
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.242 B
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.253 B04 III
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.303 B01 I
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.303 B01 VII
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.303 G01 I
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.305 B01
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.305 B01
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
1910.305 B02
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
5(a)(1)
- Issued
- Jun 10, 2002
- Abate by
- Aug 12, 2002
General-duty citation text
N.J.S.A. 34:6A-33(a): The employer did not provide the employees with a place of employment which was free from recognized hazards. LOC: Overhead Garage Doors ! Facility Wide There existed a hazard of crushing injury/death when entering/exiting through any of the overhead garage doors of the Maintenance Facilities. Comment: Some methods of abatement would include (as set forth in ANSI standard A156.8) and the following: 1. A constant pressure actuation switch. This would always be operated in sight of the door so that it could be released and manually reversed if an obstruction was hit. 2. Installation of a reversing edge switch. This would allow an automatic closing control out of sight of the door, but would immediately reverse the direction of the door upon striking an obstruction. A variation to this option would be the use of photoelectric cells that would reverse the door when an obstruction was encountered by the beam. 3. A three-button control switch. If the following conditions are also met: (a) It is provided with a permanent placard adjacent to the switch with the following warning letters at least 1/4" high: WARNING TO PREVENT ENTRAPMENT DO NOT START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR (b) The control station and placard are located within sight of the doorway. (c) Automatic closing controls are not also installed. (d) Operator must remain at the control station and observe the door until the door is fully closed.
More inspections at Springfield Department of Public Works
View Springfield Department of Public Works's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305336836.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.