Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATLANTIC CITY HOUSING AUTHORITY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ATLANTIC CITY HOUSING AUTHORITY in SHORE PARK HOUSING HIGH RISE COMPLEX, ATLANTIC CITY, NJ 08401 (NAICS 000000). OSHA activity number 305337248.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlantic City Housing Authority — free Get an email when a new federal OSHA severe-injury report for Atlantic City Housing Authority is published. One employer, no account, unsubscribe in one click.
Site address
SHORE PARK HOUSING HIGH RISE COMPLEX
City
ATLANTIC CITY
State
NJ
ZIP
08401
Mailing
JEFFREY TOWERS, ATLANTIC CITY, NJ 08401
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
9199
Employees
6
Ownership type
B

9 citations on file for this inspection.

5(a)(1)

Serious 6 instances 6 exposed
Issued
Jun 4, 2002
Abate by
Aug 6, 2002
29 CFR 1910.5(a)(1): The employer did not provide the employees with a
place of employment which was free
from a recognized hazard.
LOC: a) Central Warehouse, Powered Overhead Door
The employees were exposed to a hazard of crushing/death when
entering/exiting through the overhead doors.
Reference: ANSI-A156.8
Comment: Feasible methods of abatement could include: 1) A constant
pressure actuation switch. This would always
be operated in sight of the door so that it could be released and manually
reversed if an obstruction was hit. 2)
Installation of a reversing edge switch. This would allow an automatic
closing control out of sight of the door, but
would immediately reverse the direction of the  door upon striking an
obstruction. A variation of this option would be
the use of photoelectric cells that would reverse the door when an
obstruction was encountered by the beam. 3) A three
button control switch. If the following conditions are met: a) It is
provided with a permanent placard adjacent to the
switch with the following warning letters at 1/4" high. WARNING- TO
PREVENT ENTRAPMENT DO NOT
START DOOR DOWNWARD UNLESS DOORWAY IS CLEAR. b) The control station and
placard are located
within sight of the doorway. c) Automatic closing controls are not
installed. d) Operator must remain at the control
station and observe the door until the door is fully closed.

1910.23 C01

Serious 6 instances 6 exposed
Issued
Jun 4, 2002
Abate by
Aug 6, 2002

1910.147 C01

Serious 6 instances 6 exposed
Issued
Jun 4, 2002
Abate by
Aug 6, 2002

1910.213 B03

Serious 6 instances 6 exposed
Issued
Jun 4, 2002
Abate by
Aug 6, 2002

1910.213 C01

Serious 6 instances 6 exposed
Issued
Jun 4, 2002
Abate by
Aug 6, 2002

1910.215 A04

Serious 6 instances 6 exposed
Issued
Jun 4, 2002
Abate by
Aug 6, 2002

1910.215 B09

Serious 6 instances 6 exposed
Issued
Jun 4, 2002
Abate by
Aug 6, 2002

1910.303 G02 II

Serious 6 instances 6 exposed
Issued
Jun 4, 2002
Abate by
Aug 6, 2002

1910.305 G01 III

Serious 6 instances 6 exposed
Issued
Jun 4, 2002
Abate by
Aug 6, 2002

View Atlantic City Housing Authority's full OSHA safety record →