SEDALIA, MO —
OSHA Inspection: SEDALIA COLD STORAGE CO.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SEDALIA COLD STORAGE CO. in 320 WEST MAIN STREET, SEDALIA, MO 65301 (NAICS 312113). OSHA activity number 305391039.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SEDALIA COLD STORAGE CO.
- Site address
- 320 WEST MAIN STREET
- City
- SEDALIA
- State
- MO
- ZIP
- 65301
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 312113
- SIC code (legacy)
- 2097
- Employees
- 15
- Ownership type
- A
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 12, 2003
- Abate by
- Sep 26, 2003
- Penalty
- Initial $1,500 · Current $100 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of ammonia exposures due to the unsafe design and operation of refrigeration systems: The refrigeration systems for Plants 1, 2 & 3 did not meet the applicable requirements for the safe design, construction, installation, and operation of refrigeration systems as prescribed in ANSI/ASHRAE Standard 15-2001, Safety Standard for Refrigeration Systems in that: (a)Plants 1, 2 & 3 - The Machinery Rooms did not conform to Class 1, Division 2, of the National Electric Code when the employer provided neither continuously run mechanical ventilation systems that would actuate alarms upon failure of the ventilation systems, nor detectors located in areas where refrigerant (ammonia) from leaks would concentrate, that would actuate alarms and mechanical ventilation systems at concentrations of 1000 ppm ammonia (ANSI/ASHRAE 15-2001, Section 8.12h). (b)Plant 2 Machinery Room - Pressure relief devices did not discharge to the atmosphere at a location not less than 15 ft (4.57 m) above the adjoining ground level. The pressure relief devices were located approximately 6.5 ft above ground level (ANSI/ASHRAE 15-2001, Section 9.7.8.2). (c)Plants 1, 2 & 3 - Systems containing more than 110 lb (50kg) of refrigerant were not provided with durable signs having letters not less that 0.5 in. (12.7 mm) in height designating the kind of refrigerant or secondary coolant contained in exposed piping outside the machinery rooms (ANSI/ASHRAE 15-2001, Section 11.2.2). (d)Plant 1 Locker Room Freezer and Plant 2 "Small Freezer" - Refrigeration systems were not kept accessible at all times in that ammonia refrigeration piping and associated valves were covered with abnormal ice formations (ANSI/ASHRAE 15-2001, Section 11.6). While ultimate responsibility for correcting the hazards rests with the employer, given his/her superior knowledge of the workplace, feasible and acceptable methods to correct these hazards, among others, include: (1)In the Machinery Rooms, provide continuously run mechanical ventilation systems that would actuate alarms upon failure of the ventilation systems, or install detectors, located in areas where refrigerant from leaks would concentrate, that actuates alarms and mechanical ventilation at levels of 1000 ppm ammonia. (2)Discharge ammonia from pressure relief devices to the atmosphere at a location not less than 15 ft (4.57m) above the adjoining ground level. (3)Provide systems containing more than 110 lb (50kg) of refrigerant with durable signs having letters no less than 0.5 in. (12.7 mm) in height designating the kind of refrigerant or secondary coolant contained in exposed piping outside the machinery rooms. (4)Remove abnormal ice formations from refrigeration systems. Abatement Note: Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $100.00
- — Z (S) $1500.00
5(a)(1)
- Issued
- Aug 12, 2003
- Abate by
- Sep 26, 2003
- Penalty
- Initial $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of ammonia exposures from failure of ammonia refrigeration system components: (a)Plants 1, 2 & 3 - The ammonia refrigerating systems were not inspected and maintained in accordance with the applicable requirements prescribed in the IIAR Bulletin No. 110 (3/93), Guidelines for Start-up, Inspection and Maintenance of Ammonia Mechanical Refrigerating Systems. While ultimate responsibility for correcting the hazards rests with the employer, give his/her superior knowledge of the workplace, feasible and acceptable methods to correct these hazards, among others, include: (1)Ensure that an independent competent person conducts and documents a full inspection of the ammonia refrigerating systems at Plants 1, 2 & 3. Abatement Note: Abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S)
- — Z (S) $1500.00
1910.37 A03
- Issued
- Aug 12, 2003
- Abate by
- Aug 15, 2003
- Penalty
- Initial $525 · Current $100 Reduced
Recent events (2)
- — I (S) $100.00
- — Z (S) $525.00
1910.37 B02
- Issued
- Aug 12, 2003
- Abate by
- Sep 26, 2003
- Penalty
- Initial $225
Recent events (2)
- — I (S)
- — Z (S) $225.00
1910.120 Q01
- Issued
- Aug 12, 2003
- Abate by
- Sep 26, 2003
- Penalty
- Initial $1,500 · Current $100 Reduced
Recent events (2)
- — I (S) $100.00
- — Z (S) $1500.00
1910.151 C
- Issued
- Aug 12, 2003
- Abate by
- Aug 15, 2003
- Penalty
- Initial $375
Recent events (2)
- — I (O)
- — Z (S) $375.00
1910.303 G02 I
- Issued
- Aug 12, 2003
- Abate by
- Aug 22, 2003
- Penalty
- Initial $225
Recent events (2)
- — I (S)
- — Z (S) $225.00
1910.305 B01
- Issued
- Aug 12, 2003
- Abate by
- Aug 22, 2003
- Penalty
- Initial $225
Recent events (2)
- — I (O)
- — Z (S) $225.00
1910.305 B02
- Issued
- Aug 12, 2003
- Abate by
- Aug 15, 2003
Recent events (2)
- — I (O)
- — Z (S)
1910.132 D01
- Issued
- Aug 12, 2003
- Abate by
- Sep 26, 2003
Recent events (2)
- — I (O)
- — Z (O)
1910.134 C01
- Issued
- Aug 12, 2003
- Abate by
- Sep 26, 2003
Recent events (2)
- — I (O)
- — Z (O)
More inspections in this industry (NAICS 312113)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305391039.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.