CARROLLTON, TX —
OSHA Inspection: DRYWALL INTERIORS, LP
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of DRYWALL INTERIORS, LP in 2011 KELLER SPRINGS RD., CARROLLTON, TX 75006 (NAICS 238310). OSHA activity number 305467532.
Where did this inspection happen?
- Establishment
- DRYWALL INTERIORS, LP
- Site address
- 2011 KELLER SPRINGS RD.
- City
- CARROLLTON
- State
- TX
- ZIP
- 75006
- Mailing
- 2225 CENTURY CIR, IRVING, TX 75062
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- SIC code (legacy)
- 1742
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $4900.00 · Current $2450.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: Outdoor garden center at the Home Depot, Store No. 6555, construction site located at 2011 Keller Springs Road, Carrollton, Texas. During the construction of the spandrel panels, the employer used 1/4-inch diameter by 1-1/2- inch long nail drive anchors to secure the light-gauge steel frames to the masonry piers. The anchors, designed for light-duty applications, were not capable of withstanding the wind load. Employees working near, around and under the spandrel panels were exposed to the hazards of being struck and crushed-by the overturning and/or collapsing panels. Among other methods, recognized and feasible means of abatement to correct this hazard include, but are not limited to: a)Construct and secure the spandrel panels in accordance with the approved design specifications; or, b)Submit a Request For Information (RFI) to the professional of record for clarification of the proper installation procedures.
Recent events (2)
- — F (S) $2450.00
- — Z (S) $4900.00
More inspections in this industry (NAICS 238310)
HENDERSON, NV—2026-07-16 00:00:00
ROADRUNNER DRYWALL CORPORATION
BANNOCKBURN, IL—2026-07-16 00:00:00
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
NAMPA, ID—2026-07-15 00:00:00
INTERIOR SYSTEMS, INC.
BRIDGEPORT, WV—2026-07-14 00:00:00
EASLEY & RIVERS, INC.
ELLETTSVILLE, IN—2026-07-13 00:00:00
ENVIRO HEAT, LLC
More inspections in TX
RICHMOND, TX—2026-07-17 00:00:00
CORNELIUS NURSERIES, INC.
HOUSTON, TX—2026-07-17 00:00:00
HOLLOWAY HOUSTON, INC.
BONHAM, TX—2026-07-17 00:00:00
VOLUNTARY PURCHASING GROUPS, INC.
SNYDER, TX—2026-07-16 00:00:00
RNWBL
WICHITA FALLS, TX—2026-07-16 00:00:00
UNITED RENTALS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305467532.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.