KILGORE, TX —
OSHA Inspection: PERMIAN TANK & MFG., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PERMIAN TANK & MFG., INC. in 3405 SOUTH HENDERSON BLVD (HWY 259), KILGORE, TX 75662 (NAICS 332313). OSHA activity number 305470254.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PERMIAN TANK & MFG., INC.
- Site address
- 3405 SOUTH HENDERSON BLVD (HWY 259)
- City
- KILGORE
- State
- TX
- ZIP
- 75662
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332313
- SIC code (legacy)
- 3443
- Employees
- 47
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 22, 2004
- Abate by
- Jul 27, 2004
- Penalty
- Initial $3,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: Internal pressure of an atmospheric tank was allowed to exceed frangible limits of the weld design without secure means of controlling the pressure intake, which can expose an employee to a serious struck-by hazard and or fall hazard during testing procedure. Feasible means of abatement may include but are not limited to the following: a) Use of a regulator at the air pressure connection set to shut off sufficiently below frangible limits of design. b) Pressure release valve on the tank designed to meet the needs of the volume and pressure limitations of the tank welds. c) Hydrostatic testing as specified by API 650. d) Build the tanks laying on their sides, resting on roller carriages, to eliminate the need to place employee in an elevated position where they are exposed to struck-by hazards from ruptured decks as well as fall hazards.
Recent events (2)
- — F (S)
- — Z (S) $3500.00
1910.23 C01
- Issued
- Jul 22, 2004
- Abate by
- Jul 27, 2004
- Penalty
- Initial $1,750 · Current $100 Reduced
Recent events (2)
- — F (O) $100.00
- — Z (S) $1750.00
More inspections at Permian Tank & MFG., INC.
View Permian Tank & MFG., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332313)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305470254.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.