GRAND VIEW, ID —
OSHA Inspection: SIMPLOT LIVESTOCK COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SIMPLOT LIVESTOCK COMPANY, INC. in 1301 HIGHWAY 67, GRAND VIEW, ID 83624 (NAICS 000000). OSHA activity number 305512816.
Where did this inspection happen?
- Establishment
- SIMPLOT LIVESTOCK COMPANY, INC.
- Site address
- 1301 HIGHWAY 67
- City
- GRAND VIEW
- State
- ID
- ZIP
- 83624
- Mailing
- HC 85 BOX 275, GRAND VIEW, ID 83624
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 0211
- Employees
- 107
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $1250.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of flying parts: (a)Fabrication Shop: On August 7, 2002 and at time prior thereto, a tongue guard was not present on the shop-made pedestal grinder. (b)Diesel Shop: On August 7, 2002, and at times prior thereto, a tongue guard was not present on the Stellar bench grinder, model BG-6, serial number 10109. (c)Diesel Shop: On August 7, 2002, and at times prior thereto, a tongue guard was not present on the AB Quality Grinder, Simplot equipment number 00961, located on the east side of the building. (d) Gas Shop: On August 7, 2002, and at times prior thereto, tongue guards were not present for the two wheels on the shop-made grinder. (e)Tractor Shop: On August 7, 2002, and at times prior thereto, a tongue guard as present on the grinder. (f)Mill Shop: On August 7, 2002, and at times prior thereto, a tongue guard was not present on the shop-made grinder. (g) Deleted. Note: Abatement certification required for this item. AMONGST OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO EQUIP THE GRINDERS WITH ADJUSTABLE TONGUE GUARDS WHICH CAN BE ADJUSTED TO THE CONSTANTLY DECREASING DIAMETER OF THE WHEEL AND KEPT ADJUSTED SO THAT THE DISTANCE BETWEEN THE WHEEL PERIPHERY AND THE ADJUSTABLE TONGUE SHALL NEVER EXCEED ONE-FOURTH INCH AS REQUIRED BY ANSI B7.1-1970. ALSO EQUIP THE BIT SHARPENER WITH A WORK REST ADJUST TO WITHIN ONE-EIGHTH INCH OF THE WHEEL PERIPHERY AS REQUIRED BY ANSI B7.1-1970.
Recent events (2)
- — I (S) $1250.00
- — Z (S) $2500.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $1250.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of burns and smoke inhalation from fires: (a)Cook House: On August 7, 2002, a portable fire extinguishers had not received a monthly inspection, and was not charged. (b)Cook House: On August 7, 2002, a second portable fire extinguisher had not received an annual inspection and was not charged. (c) Deleted. (d)Gas Shop: On August 7, 2002, a portable fire extinguisher had not received a monthly inspection since March, 2002. (e) Deleted. (f)Diesel Shop: On August 7, 2002, the means of egress located on the east side of the work area and next to the electrical service panel was not marked with an exit sign. (g)Gas Shop: On August 7, 2002, the means of egress located on the northeast side of the work area was not marked with an exit sign. (h)Scale House: On August 7, 2002, the two means of egress for the building were not marked with a exit signs. (i)Tractor Shop: On August 7, 2002, the means of egress was not marked with an exit sign. Note: Abatement certification required for this item. AMONGST OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO CONDUCT MONTHLY INSPECTIONS OF PORTABLE FIRE EXTINGUISHERS AND ENSURE EACH EGRESS IS MARKED WITH A VISIBLE EXIT SIGN AS REQUIRED BY NFPA 10 AND NFPA 101.
Recent events (2)
- — I (S) $1250.00
- — Z (S) $2500.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $1500.00 · Current $750.00 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of electrical shock and electrocution: (a)Fab Shop: On August 7, 2002 and at times prior thereto, the electrical service panel located on the southeast side of the work area was not properly labeled. Circuit numbers one through four, seven through nine, and 11 and 12 were not labeled to indicate their purpose. (b)Diesel Shop: On August 7, 2002 and at times prior thereto, the electrical service panel located on the east side of the building was not properly labeled. Circuit numbers two, 13, 15, 21, and 23 were not labeled to indicate their purpose. (c)Gas Shop: On August 7, 2002 and at times prior thereto, the electrical service panel located on the west wall of the building was not properly labeled. The service panel did not have numbers identifying the individual circuits and circuit number eight was not labeled to indicate their purpose. (d)Tractor Shop: On August 7, 2002 and at times prior thereto, the electrical service panel, labeled L-033470, was not properly labeled. The circuits on the left side of the panel and circuit numbers 13, 19 and 21 were not labeled to indicate their purpose. (e)Diesel Shop: On August 7, 2002 and at times prior thereto, the electrical service panel located on the east side of the building did not have a front cover. (f)Gas Shop: On August 7, 2002 and at times prior thereto, overhead lamps located in the back room, uniform room and tire room were not guarded. The lamps were installed approximately 81 to 83 inches above the floor. (g)Mill Shop: On August 7, 2002 and at times prior thereto, the electrical outlet in the restroom was not equipped with a face plate. Note: Abatement certification required for this item. AMONGST OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO IDENTIFY AND LABEL ALL ELECTRICAL SERVICE PANELS AND EQUIP OVERHEAD LAMPS AND ELECTRICAL OUTLETS WITH GUARDS AND FACEPLATES AS REQUIRED BY NFPA 70-1971.
Recent events (2)
- — I (S) $750.00
- — Z (S) $1500.00
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $2000.00
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to trip and fall hazards: (a)Mill: On August 7, 2002, a floor opening approximately 22 inches by 11 inches was present on the rotary valve level above the truck loading station, exposing the workers to a trip and fall hazard. Note: Abatement certification required for this item. AMONGST OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO SECURE A COVER OVER THE FLOOR OPENING AND MARK THE WORD "HOLE" ON THE COVER.
Recent events (2)
- — I (S)
- — Z (S) $2000.00
1928.57 A07 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2000.00
1928.57 C02 I
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $1250.00 Reduced
Recent events (2)
- — I (S) $1250.00
- — Z (S) $2500.00
1928.57 C02 II
- Issued
- Abate by
Recent events (2)
- — I (O)
- — Z (S)
1928.57 C03 I
- Issued
- Abate by
- Penalty
- Initial $2500.00 · Current $1250.00 Reduced
Recent events (2)
- — I (S) $1250.00
- — Z (S) $2500.00
More inspections at SIMPLOT LIVESTOCK COMPANY, INC.
GRAND VIEW, ID—2008-04-01 00:00:00
SIMPLOT LIVESTOCK COMPANY, INC.
GRAND VIEW, ID—2002-08-06 00:00:00
SIMPLOT LIVESTOCK COMPANY, INC.
View SIMPLOT LIVESTOCK COMPANY, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
SCHENECTADY, NY—2012-01-05 00:00:00
BRUCE D. BOWMAN
BILLINGS, MT—2005-01-25 00:00:00
KGC, INC.
ROCKAWAY, NJ—2002-12-31 00:00:00
ROCKAWAY BOROUGH DPW
FOREST CITY, NC—2002-12-31 00:00:00
HARRY BRICKEY DBA A. BRICKEY CEILING COMPANY
EDGERTON, KS—2002-12-31 00:00:00
SUDDEN BOND INDUSTRIES
More inspections in ID
BOISE, ID—2026-07-16 00:00:00
RAYMOND MANAGEMENT COMPANY
MERIDIAN, ID—2026-07-15 00:00:00
TRIPLE R CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15 00:00:00
MIRZON CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15 00:00:00
EASTER SEALS - GOODWILL NORTHERN ROCKY MOUNTAINS
NAMPA, ID—2026-07-15 00:00:00
ELITE STEEL ERECTORS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305512816.