CHARLOTTESVILLE, VA —
OSHA Inspection: VIRGINIA DEPARTMENT OF TRANSPORTATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VIRGINIA DEPARTMENT OF TRANSPORTATION in CHARLOTTESVILLE RESIDENCY, CHARLOTTESVILLE, VA 22901 (NAICS 811111). OSHA activity number 305674053.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VIRGINIA DEPARTMENT OF TRANSPORTATION
- Site address
- CHARLOTTESVILLE RESIDENCY
- City
- CHARLOTTESVILLE
- State
- VA
- ZIP
- 22901
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 811111
- SIC code (legacy)
- 7538
- Employees
- 8
- Ownership type
- C
- Industry flags
- Manufacturing safety.
Citations
6 citations on file for this inspection.
510001 A
- Issued
- Mar 24, 2003
- Abate by
- Apr 26, 2003
General-duty citation text
Code of Virginia - 40.1-51.1(a): The employer, Virginia Department of Transportation, did not furnish a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were operating a 2-ton ATD hydraulic/mobile hoist; a 2-ton Budget hand chain operated hoist, and a 1 ton Philadelphia hand chain operated hoist in the main shop, that had not been inspected in intervals required by the American National Standards Institute (ANSI) B30.16-1987. At the Charlottesville Residency shops, a 2 ton ATD- hydraulic hoist; a 1 ton Philadelphia & a 2 ton Budget hand chain operated hoists had not been inspected, monthly or annually, and records maintained of those inspections. Specifically frequent (monthly) visual inspections of all controls and operating mechanisms safety devices, hooks, chains, and chain stretch must be conducted; periodic (annual) documented inspections of loose bolts, excessive wear of chain, chain stretch, hook, supporting structure, and end connections of load chains must be conducted; and a written, dated, and signed inspection report and record to indicate required inspection must been completed for items inspected inspected during an annual inspection. Among other methods, one feasible and acceptable method to correct this hazards id to conduct monthly inspection such as that call for by ANSI B30.16- 1987, American national Standard Safety Code for Hoists.
1910.125 F03
- Issued
- Mar 24, 2003
- Abate by
- Apr 10, 2003
1910.305 A02 IIIF
- Issued
- Mar 24, 2003
- Abate by
- Apr 10, 2003
1910.157 G02
- Issued
- Mar 24, 2003
- Abate by
- Apr 26, 2003
1910.178 L04 III
- Issued
- Mar 24, 2003
- Abate by
- Apr 26, 2003
1910.244 A01 II
- Issued
- Mar 24, 2003
- Abate by
- Apr 10, 2003
More inspections at Virginia Department of Transportation
View Virginia Department of Transportation's full OSHA safety record →
More inspections in this industry (NAICS 811111)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305674053.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.