Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE BUILDING CENTER, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE BUILDING CENTER, INC. in 413 N. POLK STREET, PINEVILLE, NC 28134 (NAICS 000000). OSHA activity number 305675969.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Building Center, INC. — free Get an email when a new federal OSHA severe-injury report for The Building Center, INC. is published. One employer, no account, unsubscribe in one click.
Site address
413 N. POLK STREET
City
PINEVILLE
State
NC
ZIP
28134
Mailing
P O BOX 357, PINEVILLE, NC 28134
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
2439
Employees
30
Ownership type
A
Industry flags
Manufacturing safety.

2 citations on file for this inspection.

95012901

Serious Gravity 05 1 instance 3 exposed
Issued
Aug 1, 2002
Abate by
Aug 19, 2002
Penalty
Initial $1,250 · Current $1,250
North Carolina General Statute 95-129(1) of the Occupational Safety
and Health Act of North Carolina:  The employer did not furnish to
each of his employees conditions of employment and a place of
employment which were free from recognized hazards that were
causing or likely to cause death or serious physical harm to
employees:
a)roof truss production area, operators of the MiTek Roof
Glider were not provided with training per manufacturer's
operator manual instructions.
One feasible and acceptable method to correct this hazard
is to provide and ensure that the operators are
thoroughly familiar with the instructions on operating
the MiTek Roof Glider as provided in section II and III
of the MiTek Industries, Inc. Roofglider Operating and
Maintenance Manual.  This instruction includes, but is
not limited to:
(1)inspecting the area around the machine prior to
starting it;
(2)testing the machine operations including the
emergency safety bars and emergency stop controls
(3)becoming familiar with the warnings, such as "Never
operate the Roof glider without all guards in place
and operational."

1910.212 A01

Serious Gravity 05 2 instances 3 exposed
Issued
Aug 1, 2002
Abate by
Aug 6, 2002
Penalty
Initial $1,250 · Current $1,250

View The Building Center, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305675969.