OSHA Inspection: INTERSTATE PLUMBING & AIR CONDITIONING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of INTERSTATE PLUMBING & AIR CONDITIONING, LLC in 8335 LAS VEGAS BLVD., SOUTH, LAS VEGAS, NV 89123 (NAICS 000000). OSHA activity number 305695488.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Interstate Plumbing & AIR Conditioning, LLC — free Get an email when a new federal OSHA severe-injury report for Interstate Plumbing & AIR Conditioning, LLC is published. One employer, no account, unsubscribe in one click.
Site address
8335 LAS VEGAS BLVD., SOUTH
City
LAS VEGAS
State
NV
ZIP
89123
Mailing
5520 STEPHANIE STREET, LAS VEGAS, NV 89122
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1711
Employees
30
Ownership type
A
Industry flags
Construction safety.

4 citations on file for this inspection.

1926.501 B04 II

Repeat Gravity 01 2 instances 1 exposed
Issued
Aug 9, 2002
Abate by
Aug 14, 2002
Penalty
Initial $2,000 · Current $200 Reduced
Recent events (2)
  • — I (R) $200.00
  • — Z (R) $2000.00

618037501

Deleted Serious Gravity 03 1 instance 5 exposed
Issued
Aug 9, 2002
Abate by
Aug 14, 2002
Penalty
Initial $2,125
Nevada Revised Statute 618.375 (1):  The employer failed to furnish
employment and a place
of employment which was free from recognized hazards that were causing or
were likely to
cause death or serious physical harm to his employees:
The employer failed to ensure that employees had knowledge of the Genie
material lift, model
SLC-24, for proper operation to recognize tip-over hazards, as follows:
a.Cancun Resort, Building #3, sub-terrain parking area, electrical room,
north wall,
employees had raised A/C unit to the ceiling with the Genie lift, model
SLC-24.
The lift was placed on a concrete slab for electrical equipment with
extended
front legs to hold the unlevel load and the lift.  The material lift was
not on a
firm, level surface.  The stabilizers were not utilized and blocks were
used in an
attempt to partially level the front legs.
Reference:  Genie Superlift Contractor, Operator's Manual, Page 2 - Safety
Rules/tip over hazards:  Do not raise the load unless the stabilizers and
legs have
been fully lowered and locked and the casters are in full contact with the
ground.
Do not use blocks to level the machine.
One feasible and acceptable abatement method, among others, to correct this
hazard would be:  1) Ensure that stabilizers are attached prior to the
load being
raised; 2) Fully train each employee in accordance with Genie Superlift
Operator's Manual prior to the lift being used; and, 3) Maintain the
Operator's
Manual with the lift for employee reference.
Recent events (2)
  • — I (S)
  • — Z (S) $2125.00

1926.306 B03 III

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Aug 5, 2002
Abate by
Aug 16, 2002

1926.1051 A03

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Aug 5, 2002
Abate by
Aug 8, 2002

View Interstate Plumbing & AIR Conditioning, LLC's full OSHA safety record →