ROLESVILLE, NC ·
OSHA Inspection: ROLESVILLE RURAL FIRE DEPARTMENT, INC.
Unprogrammed Related inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Related health inspection of ROLESVILLE RURAL FIRE DEPARTMENT, INC. in 104 EAST YOUNG STREET, ROLESVILLE, NC 27571 (NAICS 922160). OSHA activity number 305723090.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROLESVILLE RURAL FIRE DEPARTMENT, INC.
- Site address
- 104 EAST YOUNG STREET
- City
- ROLESVILLE
- State
- NC
- ZIP
- 27571
- Mailing
- P.O. BOX 249, ROLESVILLE, NC 27571
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 922160
- SIC code (legacy)
- 9224
- Employees
- 35
- Ownership type
- A
Citations
2 citations on file for this inspection.
95012901
- Issued
- Dec 17, 2002
- Abate by
- Feb 5, 2003
- Penalty
- Initial $250 · Current $250
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an improperly tested fire hose used in an emergency situation: a)fire scene, 7129 Linda Ray Rd., Zebulon, October 3, 2002 - where a Rolesville Rural Fire Department firefighter was operating Tanker #158 during a tanker shuttle assist to Hopkins Fire Department and was also in a "relay-pumping/nurse feeding" operation (relaying water from pumper-tanker to tanker) with Wendell Fire Department and in doing so, used a 25-foot piece of 3-inch double jacket hose that was not service tested properly to ensure that the hose did not slip from its coupling. Some feasible and acceptable abatement methods to correct this hazard are to provide a written policy on service testing hose, ensure all firefighters testing hose are trained on how to do so, and maintain accurate hose test records according to NFPA 1962, Chapter 3. (Reference: Section 5-5.2.4 of the National Fire Protection Association (NFPA) 1962 Standard for the Care, Use, and Service Testing of Fire Hose Including Couplings and Nozzles, 1998 Edition).
95012901
- Issued
- Dec 17, 2002
- Abate by
- Feb 5, 2003
General-duty citation text
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an improperly tested fire hose used in an emergency situation: a)fire scene, 7129 Linda Ray Rd., Zebulon, October 3, 2002 and fire station - where a Rolesville Rural Fire Department firefighter used a 25-foot piece of 3-inch double jacket hose to receive water from a Wendell Fire Department tanker and that hose along with other in-service fire hoses such as an Angus 50-foot, 3-inch rubber hose were tested at a service test pressure of 200 psi instead of the required 250 psi and 300 psi, respectively. Some feasible and acceptable abatement methods to correct this hazard, are to provide a written policy on service testing hose, recheck all in-service hose and retest as necessary, and ensure all hose testing equipment is calibrated and up-to-date. (Reference: Section 5-1.3 of the National Fire Protection Association (NFPA) 1962 Standard for the Care, Use, and Service Testing of Fire Hose Including Couplings and Nozzles, 1998 Edition).