Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EMECO INDUSTRIES, INCORPORATED

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EMECO INDUSTRIES, INCORPORATED in 805 WEST ELM AVENUE, HANOVER, PA 17331 (NAICS 337127). OSHA activity number 305835175.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Emeco Industries, Incorporated — free Get an email when a new federal OSHA severe-injury report for Emeco Industries, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
805 WEST ELM AVENUE
City
HANOVER
State
PA
ZIP
17331
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337127
SIC code (legacy)
2599
Employees
24
Ownership type
A

13 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 6 instances 20 exposed
Issued
Feb 27, 2003
Abate by
Nov 30, 2003
Penalty
Initial $1,050 · Current $575 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment
and a place of employment which were free from recognized hazards that
were causing or likely to cause
death or serious physical harm to employees in that employees were exposed
to severe burn injuries from the
potential dust explosion hazard that could have resulted from, or been
exacerbated by the lack of any dust
collection system, the location of the dust collectors in Class II
Division I area, the use of non-conductive and
corrugated ductwork, the use of improperly designed dust collectors, the
use of unapproved clean-up tools and
the use of overhead water sprinkler system:
(a)Sanding Area - Employees sanded aluminum chairs and chair components
using hand-held
pneumatic powered sanders at five work stations, hand-held pneumatic
powered sand-o-flexes
at four work stations, hand-held pneumatic powered buzzing and burring
tools at two work
stations, and a sanding belt mounted on a pedestal Bradford Admiral buffer
polisher. None of
the sanding devices, which produced fine particles of aluminum, were
attached to a dust
collection system, on or about January 9, 2003.
(b)Buffing and Polishing Room - The Torit dry-type dust collector, model
219,
serial number
24606, was not located outside the building nor were barriers located
between the dust
collector and personnel. The ductwork was not constructed of a conductive
material with a
smooth interior but rather were corrugated and nonconductive. Duct
velocities ranged from
157 to 295 feet per minute. The dust collector and ductwork were not
bonded or grounded.
The ductwork had numerous bends and some blanked off branches which
created dead spaces
for the accumulation of explosive aluminum dust. The dust collector system
did not have filter
medium that would dissipate static electrical charge nor was the collector
designed with
deflagration vents. The fan was not located on the clean air side of the
collector to prevent the
aluminum dust particles from making contact with the high speed moving
parts. The dust
collector and ductwork were not cleaned on a regular basis. Waste material
from the dust
collector was not mixed with an inert material in a five (5) to one (1)
ratio and placed in a
metal container, on or about January 9, 2003.
(c)Buffing and Polishing Room - Employees used brooms with synthetic
bristles and steel shovels
to clean up aluminum dust on the floor. Employees also used compressed air
to blown down
surfaces, on or about January 9, 2003.
(d)Sanding Area - Employees used brooms with synthetic bristles and steel
shovels to clean up
aluminum dust on the floor, on or about January 9, 2003.
(e)Buffing and Polishing Room - The room was protected by an automatic
sprinkler system.
However, in the event of a fire, the overhead sprinklers releasing water
may generate
hydrogen gas when mixed with aluminum dust and create a potential gas
explosion, on or
about January 9, 2003.
(f)Sanding Area - The area was protected by an automatic sprinkler system.
However, in the
event of a fire, the overhead sprinklers releasing water may generate
hydrogen
gas when
mixed with aluminum dust and create a potential gas explosion, on or about
January 9, 2003.
AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO
CORRECT THESE HAZARDS INCLUDES, FOLLOWING NFPA 651, STANDARD FOR MACHINING
AND FINISHING OF ALUMINUM AND THE PRODUCTION AND HANDLING OF ALUMINUM
POWDERS, 1998 EDITION, INCLUDING, BUT NOT LIMITED TO: EQUIP MACHINES THAT
PRODUCE FINE PARTICLES OF ALUMINUM WITH HOODS, CAPTURE DEVICES, OR
ENCLOSURES CONNECTED TO A DUST COLLECTION SYSTEM; LOCATE DRY-TYPE DUST
COLLECTORS OUTSIDE OF BUILDINGS; PROVIDE BARRIERS OR OTHER MEANS FOR
PROTECTING PERSONNEL NEAR DUST COLLECTORS; CONSTRUCT DUCTWORK OF
CONDUCTIVE MATERIAL WITH SMOOTH INTERIOR SURFACES; DESIGN DUCTWORK TO
MAINTAIN A MINIMUM VELOCITY OF 4500 FEET PER MINUTE AND TO HANDLE
AVOLUMETRIC FLOW RATE THAT KEEPS DUST LOADING SAFELY BELOW THE MINIMUM
EXPLOSIBLE CONCENTRATION; BOND AND GROUND THE ENTIRE DUST COLLECTION SYSTEM
AND DUST-PRODUCING EQUIPMENT; USE CONDUCTIVE, STATIC DISSIPATING DUST
COLLECTOR BAGS; INSTALL A DUST COLLECTOR WITH DEFLAGRATION VENTS; USE A
DUST
COLLECTOR THAT HAS THE FAN LOCATED ON THE CLEAN SIDE OF THE DUST COLLECTOR;
ESTABLISH A MAINTENANCE PROGRAM FOR EMPTYING THE DUST COLLECTOR AT LEAST
ONCE A DAY AND CLEAN THE DUCTWORK PERIODICALLY; MIX WASTE MATERIAL WITH AN
INERT MATERIAL IN A VOLUME RATIO OF FIVE (5) PARTS INERT TO ONE (1) PART
ALUMINUM DUST; USE CONDUCTIVE, NON-SPARKING SHOVELS AND BROOMS OR BRUSHES
WITH NATURAL FIBER BRISTLES FOR CLEANING; ELIMINATE WATER AS AN
EXTINGUISHING
AGENT IN THE ALUMINUM DUST AREAS;
VERIFICATION REQUIRED
Recent events (3)
  • — P (S) $575.00
  • — I (S) $575.00
  • — Z (S) $1050.00

1910.22 A01

Serious Gravity 02 2 instances 20 exposed
Issued
Feb 27, 2003
Abate by
Apr 1, 2003
Penalty
Initial $600 · Current $330 Reduced
Recent events (2)
  • — I (S) $330.00
  • — Z (S) $600.00

1910.132 A

Serious Gravity 02 1 instance 20 exposed
Issued
Feb 27, 2003
Abate by
Apr 1, 2003
Penalty
Initial $600 · Current $330 Reduced
Recent events (2)
  • — I (S) $330.00
  • — Z (S) $600.00

1910.157 D01

Serious Gravity 02 1 instance 1 exposed
Issued
Feb 27, 2003
Abate by
Apr 1, 2003
Penalty
Initial $600 · Current $330 Reduced
Recent events (2)
  • — I (S) $330.00
  • — Z (S) $600.00

1910.242 B

Serious Gravity 02 1 instance 1 exposed
Issued
Feb 27, 2003
Abate by
Apr 1, 2003
Penalty
Initial $600 · Current $330 Reduced
Recent events (2)
  • — I (S) $330.00
  • — Z (S) $600.00

1910.307 B

Serious Gravity 02 1 instance 1 exposed
Issued
Feb 27, 2003
Abate by
Nov 30, 2003
Penalty
Initial $600 · Current $330 Reduced
Recent events (3)
  • — P (S) $330.00
  • — I (S) $330.00
  • — Z (S) $600.00

1910.1200 E01

Serious Gravity 02 1 instance 20 exposed
Issued
Feb 27, 2003
Abate by
Apr 1, 2003
Penalty
Initial $600 · Current $330 Reduced
Recent events (2)
  • — I (S) $330.00
  • — Z (S) $600.00

1910.1200 H01

Serious Gravity 02 1 instance 20 exposed
Issued
Feb 27, 2003
Abate by
Apr 1, 2003

1910.1200 F05 I

Serious Gravity 02 1 instance 1 exposed
Issued
Feb 27, 2003
Abate by
Apr 1, 2003
Penalty
Initial $600 · Current $330 Reduced
Recent events (2)
  • — I (S) $330.00
  • — Z (S) $600.00

1910.1200 F05 II

Serious Gravity 02 1 instance 1 exposed
Issued
Feb 27, 2003
Abate by
Apr 1, 2003

1910.145 C03

Serious Gravity 02 1 instance 1 exposed
Issued
Feb 27, 2003
Abate by
Apr 1, 2003

1910.134 C02 II

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Feb 27, 2003
Abate by
Apr 1, 2003

1910.134 E05 I

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Feb 27, 2003
Abate by
Mar 4, 2003

View Emeco Industries, Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305835175.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.