PHILIPSBURG, PA —
OSHA Inspection: J & E PLUMBING & HEATING, INCORPORATED
Special Programs inspection · Safety discipline
At a glance
On , OSHA opened a special Programs safety inspection of J & E PLUMBING & HEATING, INCORPORATED in SINTERSTAHL, MOSHANNON VALLEY REG. BUS. PARK, PHILIPSBURG, PA 16866 (NAICS 238220). OSHA activity number 305837783.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J & E PLUMBING & HEATING, INCORPORATED
- Site address
- SINTERSTAHL, MOSHANNON VALLEY REG. BUS. PARK
- City
- PHILIPSBURG
- State
- PA
- ZIP
- 16866
- Mailing
- 1493 TURNPIKE AVENUE, CLEARFIELD, PA 16830
What kind of inspection was it?
- Inspection type
- Special Programs (K)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 238220
- SIC code (legacy)
- 1711
- Employees
- 5
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Aug 20, 2003
- Abate by
- Sep 16, 2003
- Penalty
- Initial $600 · Current $390 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards: (a)Inside Sinterstahl Building - Two (2) plumbers worked approximately 20 feet above the floor, from the platform of a JLG boom-supported aerial lift. These employees did not use personal fall arrest systems while working from the lift, on or about July 15, 2003. Among other methods, one feasible and acceptable method to correct this hazard includes using a personal fall arrest system, with the lanyard attached to the boom or basket of the lift, as outlined in the American National Standards Institute safety standard for Boom-Supported Elevating Work Platforms (ANSI/SIA A92.5-1992). OR IN THE ALTERNATIVE 29 CFR 1926.453(b)(2)(v): Employee body harness and lanyard assembly was not attached to the boom or basket when working from an aerial lift. (a)Inside Sinterstahl Building - Two (2) plumbers worked approximately 20 feet above the floor, from the platform of a JLG boom-supported aerial lift. These employees did not use personal fall arrest systems while working from the lift, on or about July 15, 2003. VERIFICATION REQUIREDTION
Recent events (2)
- — I (S) $390.00
- — Z (S) $600.00