Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J & E PLUMBING & HEATING, INCORPORATED

Special Programs inspection · Safety discipline

On , OSHA opened a special Programs safety inspection of J & E PLUMBING & HEATING, INCORPORATED in SINTERSTAHL, MOSHANNON VALLEY REG. BUS. PARK, PHILIPSBURG, PA 16866 (NAICS 238220). OSHA activity number 305837783.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J & E Plumbing & Heating, Incorporated — free Get an email when a new federal OSHA severe-injury report for J & E Plumbing & Heating, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
SINTERSTAHL, MOSHANNON VALLEY REG. BUS. PARK
City
PHILIPSBURG
State
PA
ZIP
16866
Mailing
1493 TURNPIKE AVENUE, CLEARFIELD, PA 16830
Inspection type
Special Programs (K)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
238220
SIC code (legacy)
1711
Employees
5
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 2 exposed
Issued
Aug 20, 2003
Abate by
Sep 16, 2003
Penalty
Initial $600 · Current $390 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to fall hazards:
(a)Inside Sinterstahl Building - Two (2) plumbers worked approximately 20
feet
above the floor, from the platform of a JLG boom-supported aerial lift.
These
employees did not use personal fall arrest systems while working from the
lift,
on or about July 15, 2003.
Among other methods, one feasible and acceptable method to correct this
hazard includes using
a personal fall arrest system, with the lanyard attached to the boom or
basket of the lift, as
outlined in the American National Standards Institute safety standard for
Boom-Supported
Elevating Work Platforms (ANSI/SIA A92.5-1992).
OR IN THE ALTERNATIVE
29 CFR 1926.453(b)(2)(v):  Employee body harness and lanyard assembly was
not attached to
the boom or basket when working from an aerial lift.
(a)Inside Sinterstahl Building - Two (2) plumbers worked approximately 20
feet
above the floor, from the platform of a JLG boom-supported aerial lift.
These
employees did not use personal fall arrest systems while working from the
lift,
on or about July 15, 2003.
VERIFICATION REQUIREDTION
Recent events (2)
  • — I (S) $390.00
  • — Z (S) $600.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305837783.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.