Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HARMONY PRODUCTS, INC. DBA HARMONY SECURITY PROD.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HARMONY PRODUCTS, INC. DBA HARMONY SECURITY PROD. in 20 CHURCH ROAD, EMIGSVILLE, PA 17318 (NAICS 332321). OSHA activity number 305838575.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Harmony Products, INC. DBA Harmony Security Prod. — free Get an email when a new federal OSHA severe-injury report for Harmony Products, INC. DBA Harmony Security Prod. is published. One employer, no account, unsubscribe in one click.
Site address
20 CHURCH ROAD
City
EMIGSVILLE
State
PA
ZIP
17318
Mailing
20 CHURCH ROAD, EMIGSVILLE, PA 17318
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
332321
SIC code (legacy)
3442
Employees
15
Ownership type
A
Industry flags
Manufacturing safety.

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 02 1 instance 1 exposed
Issued
Nov 4, 2003
Abate by
Dec 2, 2003
Penalty
Initial $300 · Current $195 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employmnent and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to a crushing type injury from press brake operations:
(a)Shop - The foot pedal on the Cincinnati thirty (30) ton mechanical
power press
brake was not provided with a means to inhibit unintentional actuation, on
or
about October 23, 2003.
One feasible means for abatement of this item among others is to provide a
protective cover over
the pedal or provide a mechanical locking pin.
OR IN THE ALTERNATIVE
29 CFR 1910.212(a)(1):  Machine guarding was not provided to protect
operators and other
employees from hazards created by the unprotected foot pedal(s) on the
press brake(s):
(a)Shop - The foot pedal on the Cincinnati thirty (30) ton mechanical
power press
brake was not provided with a means to inhibit unintentional actuation, on
or
about October 23, 2003.
VERIFICATION REQUIRED
Recent events (2)
  • — I (S) $195.00
  • — Z (S) $300.00

1910.212 A01

Serious Gravity 02 1 instance 1 exposed
Issued
Nov 4, 2003
Abate by
Dec 2, 2003

1910.212 A03 II

Serious Gravity 02 1 instance 1 exposed
Issued
Nov 4, 2003
Abate by
Dec 2, 2003
Penalty
Initial $300 · Current $195 Reduced
Recent events (2)
  • — I (S) $195.00
  • — Z (S) $300.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305838575.