Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TWITCHELL CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of TWITCHELL CORPORATION in 4031 ROSS CLARK CIRCLE N.W., DOTHAN, AL 36304 (NAICS 313210). OSHA activity number 305867996.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Twitchell Corporation — free Get an email when a new federal OSHA severe-injury report for Twitchell Corporation is published. One employer, no account, unsubscribe in one click.
Site address
4031 ROSS CLARK CIRCLE N.W.
City
DOTHAN
State
AL
ZIP
36304
Mailing
P.O. BOX 8156, DOTHAN, AL 36304
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313210
SIC code (legacy)
2221
Employees
425
Ownership type
A

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 2 exposed
Issued
Apr 22, 2003
Abate by
May 9, 2003
Penalty
Initial $1,875 · Current $1,875
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employee(s)
were exposed to the hazard of an explosion or fire due to the ignition of
a combustible dust by
static discharge:
a)Extruder Area:  Non-conducting flexible duct lines used to connect the
metal pellet
supply lines to the extruders create a potential for static build up
during the transfer of
pellets.  If a combustible concentration of dust is present during the
transfer, static
discharge could result in an explosion and/or fire, exposing employees to
the hazards of
serious thermal burns and/or being struck by debris (in the event of an
explosion).
Among others, one feasible means of abatement to correct this hazard would
be
to follow
the recommendations of NFPA 654, "Standard for Prevent of Fire and Dust
Explosions
from the Manufacturing, Processing and Handling of Combustible Particulate
Solids,"
2000 Edition.  Section 5.3.1 of this standard states:" All system
components shall be
conductive.  Bonding and grounding with a resistance os less than 1.0 x
106 ohms to
ground shall be provided."

1910.22 A02

Serious Gravity 04 2 instances 4 exposed
Issued
Apr 22, 2003
Abate by
Apr 29, 2003
Penalty
Initial $1,875 · Current $1,875

1910.26 C01

Serious Gravity 04 1 instance 4 exposed
Issued
Apr 22, 2003
Abate by
Apr 29, 2003

1904.29 B01

Other-than-serious Gravity 00 1 instance 19 exposed
Issued
Apr 22, 2003
Abate by
May 9, 2003

1910.138 A

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Apr 22, 2003
Abate by
May 2, 2003

1910.1025 H01

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Apr 22, 2003
Abate by
Apr 28, 2003

1910.1025 L01 I

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Apr 22, 2003
Abate by
May 2, 2003

View Twitchell Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305867996.