LAUREL, MD ·
OSHA Inspection: APPROPRIATE TECHNICAL RESOURCES, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of APPROPRIATE TECHNICAL RESOURCES, INC. in 9157 WHISKEY BOTTOM ROAD, LAUREL, MD 20723 (NAICS 000000). OSHA activity number 305920167.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- APPROPRIATE TECHNICAL RESOURCES, INC.
- Site address
- 9157 WHISKEY BOTTOM ROAD
- City
- LAUREL
- State
- MD
- ZIP
- 20723
- Mailing
- P.O. BOX 460, LAUREL, MD 20725
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3599
- Employees
- 18
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
15 citations on file for this inspection.
50104 A
- Issued
- Feb 3, 2003
- Abate by
- Feb 8, 2003
- Penalty
- Initial $750 · Current $750
General-duty citation text
Labor and Employment Article, Section 5-104(a): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a)Date of Violation:12/11/02 Location:Welding, Fabrication, and Machine Shop Areas Condition:A polyvinyl chloride (PVC) pipe, Schedule 40, was used to transport compressed air at 125 p.s.i. for use on pneumatic equipment. Among other methods, one feasible and acceptable abatement method to correct this hazard is to encase the PVC pipes in a shatter-resistant conduit (preferably metal or ABS material) of sufficient strength to provide protection from external damage and deterioration. The PVC pipe can also be completely replaced if this proves to be economically feasible.
1910.23 C01
- Issued
- Feb 3, 2003
- Abate by
- Feb 6, 2003
- Penalty
- Initial $750 · Current $750
1910.178 L01 I
- Issued
- Feb 3, 2003
- Abate by
- Mar 8, 2003
- Penalty
- Initial $450 · Current $450
1910.219 D01
- Issued
- Feb 3, 2003
- Abate by
- Feb 6, 2003
- Penalty
- Initial $750 · Current $750
1910.1200 E01
- Issued
- Feb 3, 2003
- Abate by
- Mar 8, 2003
- Penalty
- Initial $300 · Current $300
1910.1200 G08
- Issued
- Feb 3, 2003
- Abate by
- Feb 6, 2003
1910.1200 H01
- Issued
- Feb 3, 2003
- Abate by
- Mar 8, 2003
50405 B01
- Issued
- Feb 3, 2003
- Abate by
- Feb 8, 2003
50406 A01
- Issued
- Feb 3, 2003
- Abate by
- Feb 21, 2003
1910.22 D01
- Issued
- Feb 3, 2003
- Abate by
- Feb 6, 2003
1910.132 D02
- Issued
- Feb 3, 2003
- Abate by
- Feb 6, 2003
1910.132 F04
- Issued
- Feb 3, 2003
- Abate by
- Feb 6, 2003
1910.134 C02 I
- Issued
- Feb 3, 2003
- Abate by
- Mar 8, 2003
1910.178 L06
- Issued
- Feb 3, 2003
- Abate by
- Mar 8, 2003
09122303 B
- Issued
- Feb 3, 2003
- Abate by
- Feb 8, 2003
More inspections at Appropriate Technical Resources, INC.
View Appropriate Technical Resources, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in MD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305920167.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.