Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: OLIVEIRA FRAMING, INC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OLIVEIRA FRAMING, INC in LOT 81, DESTINATION DRIVE, BAYSIDE DEVELOPMENT, FENWICK ISLAND, DE 19944 (NAICS 238130). OSHA activity number 305948424.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Oliveira Framing, INC for free Get an email when a new federal OSHA severe-injury report for Oliveira Framing, INC is published. One employer, no account, unsubscribe in one click.
Site address
LOT 81, DESTINATION DRIVE, BAYSIDE DEVELOPMENT
City
FENWICK ISLAND
State
DE
ZIP
19944
Mailing
205 HERBAL STREET, FRUITLAND, MD 21826
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
SIC code (legacy)
1751
Employees
6
Ownership type
Private (A)
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Aug 8, 2005
Abate by
Aug 12, 2005
Penalty
Initial $1,500 · Current $1,500
ySection 5 (a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not
furnish employment and a place of employment which were free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to being struck by, caught in between and or
falling from a
collapsing prefabricated wood roof truss system in that the trusses were
not properly braced
to prevent their collapse.
a) Lot 81, Destination Drive, Bayside Development, Fenwick Island, DE
19944. The trusses collapsed while under going construction when the
workers
failed to properly brace the trusses (bracing was not connected with
sufficient
amount of nails) and a slight gust upset one of the trusses. On or about
06/20/05
Among others, one feasible and acceptable abatement to correct this
hazards is
to develop a roof truss erection plan in accordance to the design and
installation recommendations for the temporary bracing of roof trusses of
the
BCSI-B2 "Summary Sheet, Commentary and Recommendations for Truss
Installation and Temporary Bracing issued by the Truss Plate Institute.

View Oliveira Framing, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 305948424.