MUNDELEIN, IL —
OSHA Inspection: COMMERICAL PLASTICS COMPANY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of COMMERICAL PLASTICS COMPANY in 800 ALLENSON, MUNDELEIN, IL 60060 (NAICS 326199). OSHA activity number 305974289.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMMERICAL PLASTICS COMPANY
- Site address
- 800 ALLENSON
- City
- MUNDELEIN
- State
- IL
- ZIP
- 60060
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- SIC code (legacy)
- 3089
- Employees
- 50
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 17, 2003
- Abate by
- Feb 13, 2003
- Penalty
- Initial $525 · Current $368 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of contact with a moving saw blade: a) The DoAll band saw in the tool room was not equipped with a magnetic restart or similar device, as prescribed by the American National Standards for Metal Cutting Saws, ANSI B11.10-1990, Section 5.2.3.4, that in the event of an interruption in the electrical supply would prevent the saw from restarting automatically when power is restored. A feasible means of abatement would be to provide a magnetic restarter or similar device as required by ANSI B11.10-1990. Abatement certification is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (2)
- — I (S) $367.50
- — Z (S) $525.00
1910.147 C01
- Issued
- Jan 17, 2003
- Abate by
- Feb 13, 2003
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Commerical Plastics Company
View Commerical Plastics Company's full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 305974289.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.