CICERO, IL —
OSHA Inspection: ELECTRONIC PLATING COMPANY
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of ELECTRONIC PLATING COMPANY in 1821 S. 54TH AVE., CICERO, IL 60650 (NAICS 332812). OSHA activity number 306001108.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELECTRONIC PLATING COMPANY
- Site address
- 1821 S. 54TH AVE.
- City
- CICERO
- State
- IL
- ZIP
- 60650
- Mailing
- P. O. BOX 50469, CICERO, IL 60650
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- SIC code (legacy)
- 3999
- Employees
- 26
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
22 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 14, 2004
- Abate by
- Jan 27, 2004
- Penalty
- Initial $1,250 · Current $500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of incompatible chemical storage which would result in the release of hydrogen cyanide gas: a): On or about October 16, 2003, in the chemical storage room, an open drum of zinc cyanide was stored adjacent to bags of ammonium nitrate. Inadvertant mixing of the zinc cyanide and ammonium nitrate could result in employee exposure to hydrogen cyanide gas. b): On or about October 16, 2003, in the chemical storage room, drums of copper cyanide were stored approximately 10 feet away from drums of sulfuric acid. Inadvertant mixing of the copper cyanide and sulfuric acid could result in employee exposure to hydrogen cyanide gas. Among other methods, one feasible and acceptable method to correct the hazard is to physically separate cyanides from acids by storing cyanides in a separate storage room to prevent inadvertant mixing.tant
Recent events (2)
- — I (S) $500.00
- — Z (S) $1250.00
1910.22 A01
- Issued
- Jan 14, 2004
- Abate by
- Mar 3, 2004
- Penalty
- Initial $1,250 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $1250.00
1910.95 C01
- Issued
- Jan 14, 2004
- Abate by
- Apr 30, 2004
- Penalty
- Initial $1,250 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $1250.00
1910.124 H04
- Issued
- Jan 14, 2004
- Abate by
- Mar 31, 2004
- Penalty
- Initial $1,250 · Current $250 Reduced
0686
Recent events (2)
- — I (S) $250.00
- — Z (S) $1250.00
1910.132 A
- Issued
- Jan 14, 2004
- Abate by
- Jan 20, 2004
- Penalty
- Initial $1,250 · Current $250 Reduced
Recent events (2)
- — I (S) $250.00
- — Z (S) $1250.00
1910.132 F01
- Issued
- Jan 14, 2004
- Abate by
- Jan 20, 2004
1910.132 F04
- Issued
- Jan 14, 2004
- Abate by
- Jan 20, 2004
1910.141 G02
- Issued
- Jan 14, 2004
- Abate by
- Mar 3, 2004
- Penalty
- Initial $1,250 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $1250.00
1910.146 C01
- Issued
- Jan 14, 2004
- Abate by
- Apr 30, 2004
- Penalty
- Initial $1,250 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $1250.00
1910.146 C04
- Issued
- Jan 14, 2004
- Abate by
- Apr 30, 2004
Recent events (2)
- — I (S)
- — Z (S)
1910.151 C
- Issued
- Jan 14, 2004
- Abate by
- Jan 27, 2004
- Penalty
- Initial $1,250 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $1250.00
1910.1027 C
- Issued
- Jan 14, 2004
- Abate by
- Apr 30, 2004
- Penalty
- Initial $1,250 · Current $250 Reduced
C141
Recent events (2)
- — I (S) $250.00
- — Z (S) $1250.00
1910.1027 E01
- Issued
- Jan 14, 2004
- Abate by
- Apr 30, 2004
- Penalty
- Initial $1,250 · Current $250 Reduced
C141
Recent events (2)
- — I (S) $250.00
- — Z (S) $1250.00
1910.1027 J01
- Issued
- Jan 14, 2004
- Abate by
- Apr 30, 2004
C141
Recent events (2)
- — I (S)
- — Z (S)
1910.1027 M02 I
- Issued
- Jan 14, 2004
- Abate by
- Apr 30, 2004
C141
Recent events (2)
- — I (S)
- — Z (S)
1910.1027 G02 I
- Issued
- Jan 14, 2004
- Abate by
- Apr 30, 2004
- Penalty
- Initial $1,250 · Current $250 Reduced
Recent events (2)
- — I (S) $250.00
- — Z (S) $1250.00
1910.1027 L01 IA
- Issued
- Jan 14, 2004
- Abate by
- Apr 30, 2004
- Penalty
- Initial $1,250 · Current $250 Reduced
C141
Recent events (2)
- — I (S) $250.00
- — Z (S) $1250.00
1910.1027 L01 II
- Issued
- Jan 14, 2004
- Abate by
- Feb 3, 2004
1910.1200 F05 I
- Issued
- Jan 14, 2004
- Abate by
- Jan 20, 2004
- Penalty
- Initial $1,250 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $1250.00
1910.1200 F05 II
- Issued
- Jan 14, 2004
- Abate by
- Jan 20, 2004
1910.1200 G08
- Issued
- Jan 14, 2004
- Abate by
- Jan 20, 2004
1910.1200 H
- Issued
- Jan 14, 2004
- Abate by
- Jan 20, 2004
More inspections at Electronic Plating Company
View Electronic Plating Company's full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306001108.