KERRVILLE, TX —
OSHA Inspection: ACME BRIDGE CO., INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of ACME BRIDGE CO., INC. in 1400 BROADWAY, KERRVILLE, TX 78028 (NAICS 237310). OSHA activity number 306065459.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACME BRIDGE CO., INC.
- Site address
- 1400 BROADWAY
- City
- KERRVILLE
- State
- TX
- ZIP
- 78028
- Mailing
- 230 ACME ROAD, NEW BRAUNFELS, TX 78130
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237310
- SIC code (legacy)
- 1611
- Employees
- 14
- Ownership type
- A
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 24, 2004
- Abate by
- Feb 27, 2004
- Penalty
- Initial $3,500 · Current $1,650 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck-by falling concrete pipe: (a) On or about 10/07/03, a Catapillar 215 Excavator was lifting 2000 lb(900kg) concrete pipe with a steel chain sling, which was not approved for overhead lifting. The rated capacity was not known and the chain could break or it could slip off of the load as it did in this case. A wire rope choker sling is commonly used for this purpose and was put into service replacing the chain before work was continued. The choker sling will not break or slip off while lifting the concrete pipe. On or about 10/07/03, the concrete pipe was being placed into a 6.5 foot (2 m) deep trench at the construction site. The steel chain was approximately 20 feet (6 m) long and 3/8 inch (0.95cm) diameter. Applicable regulations for this type of chain: ANSI B30.9-1971, Table 1 " *Other grades of proof tested steel chain include Proof Coil, BBB Coil and Hi-Test Chain. These grades are not recommended for overhead lifting and therefore are not covered by this code."). Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the appropriate manufacturer's specifications for lifting devices. The following standards should be followed: ASME B30.20-1999, BELOW-THE-HOOK LIFTING DEVICES Chapter 20-1.2.1 Markings (a) Rated Load Marking. The rated load of the lifting device shall be marked on the main structure where it is visible... (b) Identification. A nameplate or other permanent marking shall be affixed displaying the following information: (1) manufacturer's name and address; (2) serial number; (3) lifter weight, if over 100 lbs (45 kg), (4) rated load. ANSI Standard, Slings, B30.9-1971 Section 9-1.2.1 Rated capacity (working load limit) for Alloy Steel Chain Slings, Section 9-1.3.1 Welded alloy steel chain slings shall have permanently affixed durable identification stating size, grade, rated capacity and sling manufacture.
Recent events (2)
- — I (S) $1650.00
- — Z (S) $3500.00
1926.251 A01
- Issued
- Feb 24, 2004
- Abate by
- Feb 27, 2004
1926.20 B01
- Issued
- Feb 24, 2004
- Abate by
- Mar 1, 2004
- Penalty
- Initial $3,500 · Current $3,500
Recent events (2)
- — I (S) $3500.00
- — Z (S) $3500.00
1926.651 K01
- Issued
- Feb 24, 2004
- Abate by
- Feb 27, 2004
- Penalty
- Current $100
Recent events (2)
- — I (S) $100.00
- — Z (S)
1926.21 B02
- Issued
- Feb 24, 2004
- Abate by
- Mar 9, 2004
- Penalty
- Initial $3,500 · Current $1,750 Reduced
Recent events (2)
- — I (S) $1750.00
- — Z (S) $3500.00
1926.602 B03
- Issued
- Feb 24, 2004
- Abate by
- Mar 1, 2004
- Penalty
- Initial $3,500 · Current $1,750 Reduced
Recent events (2)
- — I (S) $1750.00
- — Z (S) $3500.00
1926.651 C02
- Issued
- Feb 24, 2004
- Abate by
- Feb 27, 2004
- Penalty
- Initial $3,500 · Current $1,750 Reduced
Recent events (2)
- — I (S) $1750.00
- — Z (S) $3500.00
1926.651 E
- Issued
- Feb 24, 2004
- Abate by
- Feb 27, 2004
- Penalty
- Initial $3,500 · Current $1,750 Reduced
Recent events (2)
- — I (S) $1750.00
- — Z (S) $3500.00
1926.652 A01
- Issued
- Feb 24, 2004
- Abate by
- Feb 27, 2004
- Penalty
- Initial $49,000 · Current $34,300 Reduced
Recent events (2)
- — I (U) $34300.00
- — Z (W) $49000.00
More inspections at Acme Bridge CO., INC.
View Acme Bridge CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237310)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306065459.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.