OSHA Inspection: MOORE ERECTION LP

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of MOORE ERECTION LP in 15355 LAMBADA DRIVE, SAN ANTONIO, TX 78266 (NAICS 238120). OSHA activity number 306068677.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Moore Erection LP — free Get an email when a new federal OSHA severe-injury report for Moore Erection LP is published. One employer, no account, unsubscribe in one click.
Establishment
MOORE ERECTION LP
Site address
15355 LAMBADA DRIVE
City
SAN ANTONIO
State
TX
ZIP
78266
Mailing
19219 FM 2252, GARDEN RIDGE, TX 78266
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
SIC code (legacy)
1791
Employees
60
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
May 5, 2004
Abate by
May 10, 2004
Penalty
Initial $4,200 · Current $4,200
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazards of falls in that:
a) The employer did not ensure that the Genie S-65 Boom lift was operated
in accordance
with the American National Standard Institute 92.5 standard (ANSI) 92.5)
which states in
Section 7.9 that "The aerial platform shall be used in accordance with
this standard.  The user
shall ensure that before each movement of the aerial platform, if
repositioning the platform, that
the operator shall ensure the aerial platform is operated on a surface
within the limits specified
by the manufacturer. The manufacturer's operating instructions state; do
not raise or extend the
boom unless the machine is on a firm level surface.
On or about April 7, 2004, the employer allowed the Genie S-65 Boom lift
to
be operated while
on a slope surface at the Northwest corner of the building which resulted
in the fatal accident
when the boom lift tipped over. This condition was exacerbated by the wet
ground conditions
from recent rain. Among other methods, recognized and feasible means to
correct this hazard
include, but are not limited to prohibiting the use of the Genie S-65 Boom
lift on a sloped or
unlevel surface.
Recent events (2)
  • — F (S) $4200.00
  • — Z (S) $4200.00

1926.20 B02

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
May 5, 2004
Abate by
May 10, 2004
Penalty
Initial $4,200 · Current $4,200
Recent events (2)
  • — F (S) $4200.00
  • — Z (S) $4200.00

1926.351 B02

Deleted Serious Gravity 04 1 instance 4 exposed
Issued
May 5, 2004
Abate by
May 11, 2004
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — F (S) $1500.00
  • — Z (S) $1500.00

1926.453 B02 I

Serious Gravity 01 1 instance 4 exposed
Issued
May 5, 2004
Abate by
May 12, 2004
Penalty
Initial $900 · Current $900
Recent events (2)
  • — F (S) $900.00
  • — Z (S) $900.00

View Moore Erection LP's full OSHA safety record →