Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G & S BUILDERS

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of G & S BUILDERS in 601 EAST GENEVA, ELKHORN, WI 53121 (NAICS 238160). OSHA activity number 306106873.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G & S Builders — free Get an email when a new federal OSHA severe-injury report for G & S Builders is published. One employer, no account, unsubscribe in one click.
Establishment
G & S BUILDERS
Site address
601 EAST GENEVA
City
ELKHORN
State
WI
ZIP
53121
Mailing
1950 N. WISCONSIN ST, SUITE 2A, ELKHORN, WI 53121
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
SIC code (legacy)
1761
Employees
6
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 4 exposed
Issued
Sep 2, 2003
Abate by
Sep 5, 2003
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to:
On or about July 24, 2003, Elkhorn, WI -
Employees were exposed to the hazard of truss collapse due to inadequate
truss bracing.
Among other methods, feasible and acceptable abatement methods to correct
this hazard would
be to:
Comply with the Wood Truss Council of America:  "Temporary erection
bracing must
be applied to three planes of the roof system to ensure stability: Plane
1) Top Chord
(sheathing), Plane 2) Bottom Chord (ceiling plane), and Plane 3) Web
Member plane or
vertical plane perpendicular to trusses."

1926.21 B02

Serious Gravity 03 1 instance 1 exposed
Issued
Sep 2, 2003
Abate by
Sep 19, 2003
Penalty
Initial $750 · Current $750

1926.503 A01

Serious Gravity 03 1 instance 1 exposed
Issued
Sep 2, 2003
Abate by
Sep 19, 2003

View G & S Builders's full OSHA safety record →