POMPANO BEACH, FL ·
OSHA Inspection: NEXTRAN TRUCK CENTER
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of NEXTRAN TRUCK CENTER in 1490 NW 22ND STREET, POMPANO BEACH, FL 33069 (NAICS 811111). OSHA activity number 306176728.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEXTRAN TRUCK CENTER
- Site address
- 1490 NW 22ND STREET
- City
- POMPANO BEACH
- State
- FL
- ZIP
- 33069
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 811111
- SIC code (legacy)
- 7538
- Employees
- 27
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jul 31, 2003
- Abate by
- Aug 6, 2003
- Penalty
- Initial $3,500 · Current $2,625 Reduced
General-duty citation text
Section 5(A)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or were likely to cause death or serious physical harm to employees in that employees servicing a clutch were exposed to caught- in hazards: On or about 02/06/03, in the southeast corner of the mechanic's shop, employees were exposed to the hazard of being caught-in between the transmission and the clutch assembly while replacing the clutch on a mixer truck without having attached and properly secured the transmission to the transmission jack. Among other methods of abatement, one feasible and acceptable method to correct this hazard is to follow the equipment manufacturer's procedures to properly secure the transmission to the transmission jack. PLEASE NOTE: DOCUMENTATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- · I (S) $2625.00
- · Z (S) $3500.00
More inspections in this industry (NAICS 811111)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 306176728.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.