Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: DIRECTORY DISTRIBUTING ASSOCIATES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DIRECTORY DISTRIBUTING ASSOCIATES in 2670 BRECKENRIDGE BLVD., DULUTH, GA 30096 (NAICS 493110). OSHA activity number 306218280.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Directory Distributing Associates for free Get an email when a new federal OSHA severe-injury report for Directory Distributing Associates is published. One employer, no account, unsubscribe in one click.
Site address
2670 BRECKENRIDGE BLVD.
City
DULUTH
State
GA
ZIP
30096
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
SIC code (legacy)
4225
Employees
100
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 4 exposed
Issued
Feb 20, 2004
Abate by
Mar 17, 2004
Penalty
Initial $1,875 · Current $1,406 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to pinch points and being caught-in/between hazards:
a.  The employer did not ensure that the Automatic Powered Conveyors
emergency shut off
switch located on the Heat Bundling Machines was within employees reach,
exposing employees
to being caught in the rollers and not being able to shut off the
conveyors in the event of an
emergency, on or about 02/19/03.
Among other methods, one feasible and acceptable method to correct the
hazard is to relocate
the emergency shut off switch to the employees/operators work station area.
Reference - ANZI-B20.1 - Safety standard for conveyors and related
equipment, Section
5.11.2(c)(1).
Recent events (2)
  • · I (S) $1406.00
  • · Z (S) $1875.00

View Directory Distributing Associates's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306218280.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.