COLORADO SPRINGS, CO —
OSHA Inspection: ARROW MOVING & STORAGE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ARROW MOVING & STORAGE in 2885 JANITELL ROAD, COLORADO SPRINGS, CO 80909 (NAICS 493110). OSHA activity number 306226101.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARROW MOVING & STORAGE
- Site address
- 2885 JANITELL ROAD
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80909
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- SIC code (legacy)
- 4225
- Employees
- 25
- Ownership type
- A
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 22, 2003
- Abate by
- Oct 8, 2003
- Penalty
- Initial $1,250 · Current $700 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to hazards when riding the platform of the Genie Powered Superlift, when the manufacturer did not design the lift for lifting personnel: 1) On September 17, 2003, and at prior times, employees rode up on a platform on the Genie lift to access the upper storage racks. A warning label on the Genie Lift stated "no riders, material lifting only". The owner's manual stated "The Powered Superlift is a material lift only and is not to be used for lifting personnel. Among other methods, the following are feasible and acceptable methods to correct this hazardous condition: 1) Implement a storage system whereby pallets are placed under material to be stored on the racks. The Genie lift could then be used to raise and lower the material on the pallet, thus eliminating the need for employees to ride up with the lift. 2) Purchase a material lift meeting the weight limit of the mezzanine area and that is designed for employees to safely ride on the lifting platform. Abatement Note: Abatement certification is required for this item (see enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
- — I (S) $700.00
- — Z (S) $1250.00
1910.23 C01
- Issued
- Sep 22, 2003
- Abate by
- Oct 8, 2003
Recent events (2)
- — I (S)
- — Z (S)
1910.303 B01
- Issued
- Sep 22, 2003
- Abate by
- Oct 8, 2003
- Penalty
- Initial $1,000 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $1000.00
1910.303 G02 I
- Issued
- Sep 22, 2003
- Abate by
- Oct 8, 2003
Recent events (2)
- — I (S)
- — Z (S)
1910.334 A02 II
- Issued
- Sep 22, 2003
- Abate by
- Oct 8, 2003
Recent events (2)
- — I (S)
- — Z (S)
More inspections at Arrow Moving & Storage
View Arrow Moving & Storage's full OSHA safety record →