ENGLEWOOD, CO —
OSHA Inspection: SUREVOID PRODUCTS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SUREVOID PRODUCTS, INC. in 1895 W. DARTMOUTH AVE., ENGLEWOOD, CO 80110 (NAICS 322211). OSHA activity number 306226499.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUREVOID PRODUCTS, INC.
- Site address
- 1895 W. DARTMOUTH AVE.
- City
- ENGLEWOOD
- State
- CO
- ZIP
- 80110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 322211
- SIC code (legacy)
- 2653
- Employees
- 40
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
14 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 6, 2003
- Abate by
- Nov 5, 2003
- Penalty
- Initial $1,250 · Current $500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to injury from flying plastic projectiles from mechanical failure of the shop air system: (a) The employer was transporting above ground compressed air at over 120 psi through schedule 40 polyvinyl chloride (PVC) pipe. The PVC pipe was used to supply compressed air to machines and equipment. These lines are used to feed air hoses used by employees daily. The above stated hazard presented a potential for PVC explosion with likely lacerations to exposed employees from plastic shrapnel. Among other methods, the following are feasible and acceptable methods to minimize the probability of injury during the transfer of compressed air throughout the facility. 1. Follow American Society for Testing and Materials (ASTM) Standard D1785-86, which states polyvinyl chloride (PVC), pipes can be used for transportation of compressed air and gases only if the PVC pipes are made of shatter resistant material or are encased in a shatter resistant material. 2. Follow American National Standards Institute/American Society of Mechanical Engineers (ANSI/ASME) B31.8-198 Gas Transmission and Distribution Piping Systems Standard, Sections 842.32, 842.43 and 849.52(b) which limits the operating pressure of plastic piping distributions systems to 100 pounds per square inch (psi) and prohibits the installation of such systems above ground except where " the above ground portion of the plastic service line is completely enclosed in a conduit or casing of sufficient strength to provide protection from external damage and deterioration." 3. Replace all existing PVC pipes with a cast iron, or other type of approved type piping rated to transport compressed air safely above ground. Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- — I (S) $500.00
- — Z (S) $1250.00
5(a)(1)
- Issued
- Oct 6, 2003
- Abate by
- Nov 1, 2003
- Penalty
- Initial $1,250 · Current $500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to amputations: (a) Production Area: On or about September 18, 2003, the Delta Radial Arm Saw (serial number 98K91732) cutting head was not installed so that it would return to its starting position when released by the operator while notching stacks of corrugated cardboard and the saw blade extended past the work table exposing employees to contact with the blade. Among other methods, one feasible method is to install the saw with the front end of the unit slightly higher that the rear, or to add a pulley and weight to pull the head back in a manner so as to cause the cutting head to return gently to the starting position when released by the operator, and install a stop block to prevent movement of the saw past the work table, or extend the table. Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").-Certification
Recent events (2)
- — I (S) $500.00
- — Z (S) $1250.00
1910.23 C01
- Issued
- Oct 6, 2003
- Abate by
- Oct 7, 2003
- Penalty
- Initial $1,250 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $1250.00
1910.132 D01
- Issued
- Oct 6, 2003
- Abate by
- Nov 5, 2003
- Penalty
- Initial $1,000 · Current $400 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $1000.00
1910.147 C01
- Issued
- Oct 6, 2003
- Abate by
- Nov 5, 2003
- Penalty
- Initial $2,500 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2500.00
1910.157 G01
- Issued
- Oct 6, 2003
- Abate by
- Nov 5, 2003
- Penalty
- Initial $1,000 · Current $400 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $1000.00
1910.178 L06
- Issued
- Oct 6, 2003
- Abate by
- Nov 5, 2003
- Penalty
- Initial $1,000 · Current $400 Reduced
Recent events (2)
- — I (S) $400.00
- — Z (S) $1000.00
1910.212 A03 II
- Issued
- Oct 6, 2003
- Abate by
- Oct 20, 2003
- Penalty
- Initial $2,500 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2500.00
1910.212 A05
- Issued
- Oct 6, 2003
- Abate by
- Oct 20, 2003
- Penalty
- Initial $750 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $750.00
1910.219 C04 I
- Issued
- Oct 6, 2003
- Abate by
- Oct 9, 2003
- Penalty
- Initial $750 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $750.00
1910.219 D01
- Issued
- Oct 6, 2003
- Abate by
- Oct 9, 2003
- Penalty
- Initial $1,200 · Current $480 Reduced
Recent events (2)
- — I (S) $480.00
- — Z (S) $1200.00
1910.242 B
- Issued
- Oct 6, 2003
- Abate by
- Oct 20, 2003
- Penalty
- Initial $1,750 · Current $700 Reduced
Recent events (2)
- — I (S) $700.00
- — Z (S) $1750.00
1910.305 B01
- Issued
- Oct 6, 2003
- Abate by
- Oct 14, 2003
- Penalty
- Initial $750 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $750.00
1910.1200 E01
- Issued
- Oct 6, 2003
- Abate by
- Nov 5, 2003
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Surevoid Products, INC.
View Surevoid Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 322211)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306226499.