CASTLE ROCK, CO ·
OSHA Inspection: ASP WESTWARD LP DBA COLORADO COMMUNITY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ASP WESTWARD LP DBA COLORADO COMMUNITY in 319 PERRY STREET, CASTLE ROCK, CO 80104 (NAICS 511110). OSHA activity number 306227547.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASP WESTWARD LP DBA COLORADO COMMUNITY
- Site address
- 319 PERRY STREET
- City
- CASTLE ROCK
- State
- CO
- ZIP
- 80104
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 511110
- SIC code (legacy)
- 2711
- Employees
- 65
- Ownership type
- Private (A)
Citations
16 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 8, 2004
- Abate by
- May 1, 2004
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to injury from flying plastic projectiles from mechanical failure of the shop air system: (a) On or about November 12, 2003 and at times prior, employees were exposed to shrapnel injury while using compressed air without utilizing the proper piping system. Among other methods, the following are feasible and acceptable methods to minimize the probability of injury during the transfer of compressed air throughout the facility. 1. Follow American Society for Testing and Materials (ASTM) Standard D1785-86, which states polyvinyl chloride (PVC), pipes can be used for transportation of compressed air and gases only if the PVC pipes are made of shatter resistant material or are encased in a shatter resistant material. 2. Follow American National Standards Institute/American Society of Mechanical Engineers (ANSI/ASME) B31.8-198 Gas Transmission and Distribution Piping Systems Standard which limits the operating pressure of plastic piping distributions systems to 100 pounds per square inch (psi) and prohibits the installation of such systems above ground except where " the above ground portion of the plastic service line is completely enclosed in a conduit or casing of sufficient strength to provide protection from external damage and deterioration." 3. Replace all existing PVC pipes with a cast iron, or other type of approved type piping rated to transport compressed air safely above ground. Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- · I (S) $1000.00
- · Z (S) $2000.00
5(a)(1)
- Issued
- Mar 8, 2004
- Abate by
- May 1, 2004
- Penalty
- Initial $1,500 · Current $750 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the possibility of dropped loads and/or crushing hazards: (a) On or about November 12, 2003 and at times prior, employees were exposed to possible crushing injury while using the (Stearns Electric Corporation) Goss Hoist without performing frequent inspections to ensure the critical components were in good operational order. Among other methods, one feasible acceptable abatement method to correct his hazard is to: (a) Perform frequent inspections at daily to monthly intervals as per ANSI B-30-16-1.2.1.2 and 2.2.1.2 on items such as: 1.All controls and operating mechanisms for improper operation daily. 2.All safety devices for malfunction; daily. 3.Deterioration or leakage in air systems, if applicable. 4.Hooks for deformations, chemical damage, or cracks.Other load-bearing components of the hoist; daily. 5.Load-carrying ropes.Visual inspection daily for wear, twist, distortion or improper dead-ending to the hoisting drum and other attachments. Check chain also for deposits of foreign material which may be carried into the hoist mechanism. (b) Perform periodic inspections at monthly to yearly intervals as per ANSI B30.16 2.2.1.3, which includes the requirements specified above plus: 1.Loose bolts or rivets. 2.Cracked or worn drums or sheaves. 3.Worn, corroded, cracked or distorted parts such as pins, bearings, shafts, gears, rollers, locking and clamping devices. 4.Excessive wear on motor or load brake. 5.Excessive wear of chain, rope, load sprockets, drums, sheaves, and chain stretch. 6.Hooks. Dye penetrants, magnetic particle or other suitable crack detecting inspections should be performed at least once per year. 7.Electrical apparatus for signs of pitting or any deterioration of controller contractors, limit switches and push button stations. 8.Hook retaining nuts or collars and pins, welds or riveting used to secure the retaining members should be inspected. 9.Supporting structure and trolley if used shall be inspected, for continued ability to support the imposed loads. 10.Warning label for absence or illegibility. (c) Written, dated and signed inspection reports and records should be made monthly on critical items such as brakes, hooks, chains and ropes. Records should be readily available. Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Sample Abatement-Certification Letter").
Recent events (2)
- · I (S) $750.00
- · Z (S) $1500.00
1910.24 B
- Issued
- Mar 8, 2004
- Abate by
- May 1, 2004
- Penalty
- Initial $2,000 · Current $1,000 Reduced
Recent events (2)
- · I (S) $1000.00
- · Z (S) $2000.00
1910.36 H03
- Issued
- Mar 8, 2004
- Abate by
- Mar 11, 2004
- Penalty
- Initial $1,500 · Current $500 Reduced
Recent events (2)
- · I (O) $500.00
- · Z (S) $1500.00
1910.147 C01
- Issued
- Mar 8, 2004
- Abate by
- May 15, 2004
- Penalty
- Initial $5,000 · Current $2,000 Reduced
Recent events (2)
- · I (S) $2000.00
- · Z (S) $5000.00
1910.178 P01
- Issued
- Mar 8, 2004
- Abate by
- Apr 10, 2004
- Penalty
- Initial $2,000 · Current $500 Reduced
Recent events (2)
- · I (O) $500.00
- · Z (S) $2000.00
1910.219 F03
- Issued
- Mar 8, 2004
- Abate by
- Mar 12, 2004
- Penalty
- Initial $1,500 · Current $750 Reduced
Recent events (2)
- · I (S) $750.00
- · Z (S) $1500.00
1910.212 A03 II
- Issued
- Mar 8, 2004
- Abate by
- Mar 12, 2004
- Penalty
- Initial $55,000 · Current $20,000 Reduced
Recent events (2)
- · I (S) $20000.00
- · Z (W) $55000.00
1910.23 C01
- Issued
- Mar 8, 2004
- Abate by
- May 15, 2004
- Penalty
- Initial $10,000 · Current $1,000 Reduced
Recent events (2)
- · I (S) $1000.00
- · Z (R) $10000.00
1910.178 L01 I
- Issued
- Mar 8, 2004
- Abate by
- Apr 10, 2004
- Penalty
- Initial $10,000 · Current $500 Reduced
Recent events (2)
- · I (O) $500.00
- · Z (R) $10000.00
1910.242 B
- Issued
- Mar 8, 2004
- Abate by
- Mar 12, 2004
Recent events (2)
- · I (O)
- · Z (O)
1910.303 B02
- Issued
- Mar 8, 2004
- Abate by
- Mar 12, 2004
Recent events (2)
- · I (O)
- · Z (O)
1910.305 A02 I
- Issued
- Mar 8, 2004
- Abate by
- Mar 11, 2004
Recent events (2)
- · I (O)
- · Z (O)
1910.305 B02
- Issued
- Mar 8, 2004
- Abate by
- Mar 11, 2004
Recent events (2)
- · I (O)
- · Z (O)
1910.22 A01
- Issued
- Mar 8, 2004
- Abate by
- Mar 13, 2004
Recent events (2)
- · I (O)
- · Z (O)
1910.141 C01
- Issued
- Mar 8, 2004
- Abate by
- May 1, 2004
Recent events (2)
- · I (O)
- · Z (O)
More inspections at ASP Westward LP DBA Colorado Community
View ASP Westward LP DBA Colorado Community's full OSHA safety record →
More inspections in this industry (NAICS 511110)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 306227547.