LANCASTER, NY —
OSHA Inspection: PARAGON NORTHEAST CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PARAGON NORTHEAST CORPORATION in LANCASTER HIGH SCHOOL, 1 FORTON, LANCASTER, NY 14086 (NAICS 236220). OSHA activity number 306248758.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PARAGON NORTHEAST CORPORATION
- Site address
- LANCASTER HIGH SCHOOL, 1 FORTON
- City
- LANCASTER
- State
- NY
- ZIP
- 14086
- Mailing
- 434 DELAWARE AVENUE, BUFFALO, NY 14202
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- SIC code (legacy)
- 1542
- Employees
- 6
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Mar 20, 2003
- Abate by
- Mar 25, 2003
- Penalty
- Initial $625 · Current $625
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire/explosion hazard: a) On or about 2/20/03, area A on west side of bldg., at the Lancaster High School construction site, Lancaster, NY: Employees were exposed to a fire/explosion hazard because a 1000 gal. "above ground" container of propane located outside the building under construction, was being used to fuel temporary heaters inside the building. The minimum distance between this container and the masonry wall of the building was only 8 ft. 9 inches. Among others, a feasible method to eliminate or materially reduce this hazard is to move the propane container, so that all parts of the container are at least 10 ft. away from the wall of the building. This would comply with NFPA code 58, Table 3-2.2.2. ABATEMENT CERTIFICATION REQUIREDATION
Recent events (2)
- — J (S) $625.00
- — Z (S) $625.00
More inspections at Paragon Northeast Corporation
View Paragon Northeast Corporation's full OSHA safety record →
More inspections in this industry (NAICS 236220)