ONONDAGA, NY —
OSHA Inspection: CENTRAL TOWER A DIELECTRIC COMPANY
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of CENTRAL TOWER A DIELECTRIC COMPANY in WSTM TRANSMISSION FACILITY, SENTINEL HEIGHTS ROAD, ONONDAGA, NY 13215 (NAICS 237990). OSHA activity number 306309261.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CENTRAL TOWER A DIELECTRIC COMPANY
- Site address
- WSTM TRANSMISSION FACILITY, SENTINEL HEIGHTS ROAD
- City
- ONONDAGA
- State
- NY
- ZIP
- 13215
- Mailing
- 3266 TOWER DRIVE, NEWBURGH, IN 47630
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 237990
- SIC code (legacy)
- 1799
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.550 G04 III
- Issued
- Aug 12, 2003
- Abate by
- Aug 15, 2003
- Penalty
- Initial $1,500 · Current $1,050 Reduced
Recent events (2)
- — I (S) $1050.00
- — Z (S) $1500.00
1926.550 G04 IIA
- Issued
- Aug 12, 2003
- Abate by
- Aug 15, 2003
Recent events (2)
- — I (S)
- — Z (S)
5(a)(1)
- Issued
- Aug 12, 2003
- Abate by
- Aug 15, 2003
- Penalty
- Initial $6,000 · Current $4,200 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of falling: a)Tower Site, On or about 6/6/03: Employees were accessing the working level of a new Television Antenna by riding the ball of the load line to a height of approximately 860 feet above the ground, exposing employees to a fall hazard. Among other methods, feasible and acceptable abatement methods to correct these hazards are to: 1)Follow all of the requirements of CPL 2-1.36, Interim Inspection Procedures During Communication Tower Construction. Which amongst other items, would require that the employer provide: a) Proper training in regards to hoisting employees. c) The personnel load capacity and material capacity of the lifting system in use and ensure that it is posted near the lift operator. d) A trial lift of the maximum intended personnel load from the ground to the location to which personnel are to be hoisted. e) A visual inspection of the hoist, rigging, base support and foundation by a competent person immediately after the trial lift. f) A proof test of the hoist in which 125 percent of the load is suspended for 5 minutes. g) Documentation of all trial lifts. h) As-built drawings approved by a registered professional engineer, available on the site. i) The rated load capacities, recommended operating speeds, and special hazard warnings or instructions for the hoist and conspicuously post them on the hoist. j) Personnel load capacity for the current configuration of the gin pole that are posted within site of the operator. k) An accessible fire extinguisher of 5B:C minimum rating for the operators station. l) An operators manual for the hoist in use, maintained on the site. m) A hoist log book that shall record all hoist inspections, tests, maintenance, and repair. The hoist log shall be updated daily when the hoist is being used or serviced and shall be maintained on site at all times.n) That the personnel hoist be anchored to prevent movement. o) An anti two block device on the hoist and gin pole. p) That no more than two employees ride the hoist ball at one time. Central Tower A Dielectric Company was previously cited for a violation of this Occupational Safety and Health Standard or its equivalent standard, Section 5(1)(1) pertaining to communication tower work, which was contained in OSHA Inspection number 304592520, Citation 1, Item 1, issued on 01/24/03, with respect to a workplace located at the WSTM Transmission Facility, Sentinel Heights Road, Onondaga, New York.
Recent events (2)
- — I (R) $4200.00
- — Z (R) $6000.00
More inspections at Central Tower a Dielectric Company
View Central Tower a Dielectric Company's full OSHA safety record →
More inspections in this industry (NAICS 237990)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306309261.