WAUKEGAN, IL —
OSHA Inspection: WAUKEGAN STEEL SALES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WAUKEGAN STEEL SALES, INC. in 1201 BELVIDERE STREET, WAUKEGAN, IL 60085 (NAICS 332312). OSHA activity number 306400664.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WAUKEGAN STEEL SALES, INC.
- Site address
- 1201 BELVIDERE STREET
- City
- WAUKEGAN
- State
- IL
- ZIP
- 60085
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- SIC code (legacy)
- 3441
- Employees
- 70
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.219 B01
- Issued
- Apr 9, 2003
- Abate by
- May 12, 2003
- Penalty
- Initial $525 · Current $350 Reduced
Recent events (2)
- — I (S) $350.00
- — Z (S) $525.00
5(a)(1)
- Issued
- Apr 7, 2003
- Abate by
- May 30, 2003
- Penalty
- Initial $2,500 · Current $1,200 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the rotating blade: a)West Shop-Franz Haberle Model H 300A Series "C" Cold saw. b)East Shop-Do All Model 2013-V Vertical Band saw. c)North Shop-Wallace Speedy Cut No model# Cold saw. All saws identified above were not equipped with a magnetic restarter or similar device, as prescribed by American National Standards Institute (ANSI) B11.10-1990, Section 5.2.3.4, that in the event of an interruption in the electrical supply such a device would prevent the saw from restarting automatically when power is restored. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).s
Recent events (2)
- — I (S) $1200.00
- — Z (S) $2500.00
1910.147 C01
- Issued
- Apr 7, 2003
- Abate by
- May 30, 2003
- Penalty
- Initial $2,500 · Current $1,200 Reduced
Recent events (2)
- — I (S) $1200.00
- — Z (S) $2500.00
1910.212 A01
- Issued
- Apr 7, 2003
- Abate by
- May 8, 2003
- Penalty
- Initial $2,500 · Current $1,200 Reduced
Recent events (2)
- — I (S) $1200.00
- — Z (S) $2500.00
1910.212 A03 II
- Issued
- Apr 7, 2003
- Abate by
- May 30, 2003
- Penalty
- Initial $2,500 · Current $1,200 Reduced
Recent events (2)
- — I (S) $1200.00
- — Z (S) $2500.00
1910.217 B04 I
- Issued
- Apr 7, 2003
- Abate by
- May 8, 2003
- Penalty
- Initial $2,500 · Current $2,500
Recent events (2)
- — I (S) $2500.00
- — Z (S) $2500.00
1910.217 C01 I
- Issued
- Apr 7, 2003
- Abate by
- May 8, 2003
- Penalty
- Initial $2,500 · Current $2,500
Recent events (2)
- — I (S) $2500.00
- — Z (S) $2500.00
1910.242 B
- Issued
- Apr 7, 2003
- Abate by
- May 8, 2003
- Penalty
- Initial $700 · Current $350 Reduced
Recent events (2)
- — I (S) $350.00
- — Z (S) $700.00
More inspections at Waukegan Steel Sales, INC.
View Waukegan Steel Sales, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306400664.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.