WETHERSFIELD, CT —
OSHA Inspection: STEPHEN BLEVINS DBA BLEVINS TREE SERVICE
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STEPHEN BLEVINS DBA BLEVINS TREE SERVICE in 489 WOLCOTT HILL ROAD, WETHERSFIELD, CT 06129 (NAICS 561730). OSHA activity number 306409707.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STEPHEN BLEVINS DBA BLEVINS TREE SERVICE
- Site address
- 489 WOLCOTT HILL ROAD
- City
- WETHERSFIELD
- State
- CT
- ZIP
- 06129
- Mailing
- POND STREET, WINDSOR, CT 06095
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561730
- SIC code (legacy)
- 0783
- Employees
- 8
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Oct 27, 2003
- Abate by
- Dec 15, 2003
- Penalty
- Initial $6,300 · Current $3,150 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of crushing, falls, or traumatic injuries due to failure of machine components. Jobsite at 489 Wolcott Hill Road, Wethersfield, Connecticut: An employee was in an aerial lift (Asplundh Aerial Lift Model LR-50 S/N 837191 mounted on a 1982 Ford truck S/N 1X1FDXF82H9DVA38622). He fell to the ground when the hydraulic cylinder supporting the lower boom failed. Among other methods, one feasible and acceptable abatement method to correct this hazard is to: 1. Develop a formal documented inspection and preventive maintenance program for the aerial lift in accordance with American National Standards Institute Standard, ANSI A92.2 "Vehicle-Mounted Elevating and Rotating Aerial Devices" and the Asplundh Aerial Lift Manual. 2. Review section IV of the Asplundh Aerial Lift Manual which describes hydraulic cylinder maintenance and repair including how often hydraulic cylinders need to be rebuilt or replaced. Repair/replace upper and lower boom cylinders as indicated in the manual. 3. Review Asplundh Product Bulletin No. 123 dated March 5, 1999 regarding periodic replacement of upper boom cables and mandatory rebuilding of machines over 15 years old. Based on this bulletin have qualified aerial lift mechanics conduct a thorough inspection and overhaul of the aerial lift. Have a qualified engineer determine what critical components need rebuilding or replacement. Make repairs only with factory approved replacement parts.
Recent events (2)
- — I (S) $3150.00
- — Z (S) $6300.00
More inspections in this industry (NAICS 561730)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306409707.