WEISER, ID ·
OSHA Inspection: GOLDEN EAGLE CABINET SHOP, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of GOLDEN EAGLE CABINET SHOP, INC. in 514 HWY 95, WEISER, ID 83672 (NAICS 337110). OSHA activity number 306438490.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GOLDEN EAGLE CABINET SHOP, INC.
- Site address
- 514 HWY 95
- City
- WEISER
- State
- ID
- ZIP
- 83672
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- SIC code (legacy)
- 5712
- Employees
- 3
- Ownership type
- Private (A)
Citations
15 citations on file for this inspection.
5(a)(1)
- Issued
- Jun 7, 2004
- Abate by
- Sep 25, 2004
- Penalty
- Initial $600 · Current $300 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being severely burned due to inadequacies in the design and construction of the spray room: (a)Spray Room: On May 13, 2004, and at times prior thereto, employee(s) sprayed Valtec self-seal precat 20 sheen lacquer in a spray room that was constructed out of chip board material. (b)Spray Room: On May 13, 2004, and at times prior thereto, employee(s) sprayed Valtec self-seal precat 20 sheen lacquer in a spray room that was not equipped with a noncombustible fire door with shutters. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the design and construction requirements set forth in the American National Standards Institute Z9.3 section 5.1 and section 5.2. Common materials include concrete, zinc sheet metal, aluminum sheet metal, zinc coated iron, or nonflammable mastics. Materials used must be both substantially noncombustible and easily cleanable. Abatement Note: Abatement certification and documentation are required for this item.
Recent events (3)
- · P (S) $300.00
- · I (S) $300.00
- · Z (S) $600.00
1910.107 D11
- Issued
- Jun 7, 2004
- Abate by
- Sep 25, 2004
Recent events (3)
- · P (S)
- · I (S)
- · Z (S)
1910.107 E02
- Issued
- Jun 7, 2004
- Abate by
- Jun 17, 2004
Recent events (2)
- · I (S)
- · Z (S)
1910.107 G02
- Issued
- Jun 7, 2004
- Abate by
- Jul 23, 2004
Recent events (2)
- · I (S)
- · Z (S)
1910.107 G07
- Issued
- Jun 7, 2004
- Abate by
- Jun 17, 2004
Recent events (2)
- · I (S)
- · Z (S)
1910.132 A
- Issued
- Jun 7, 2004
- Abate by
- Jun 17, 2004
- Penalty
- Initial $750
Recent events (2)
- · I (O)
- · Z (S) $750.00
1910.132 D01
- Issued
- Jun 7, 2004
- Abate by
- Jun 17, 2004
Recent events (2)
- · I (O)
- · Z (S)
1910.212 A05
- Issued
- Jun 7, 2004
- Abate by
- Jun 11, 2004
- Penalty
- Initial $510 · Current $255 Reduced
Recent events (2)
- · I (S) $255.00
- · Z (S) $510.00
1910.1200 G08
- Issued
- Jun 7, 2004
- Abate by
- Jun 17, 2004
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- · I (S) $375.00
- · Z (S) $750.00
1910.1200 H
- Issued
- Jun 7, 2004
- Abate by
- Jul 1, 2004
Recent events (2)
- · I (S)
- · Z (S)
1910.134 C01
- Issued
- Jun 7, 2004
- Abate by
- Jul 23, 2004
Recent events (2)
- · I (O)
- · Z (O)
1910.134 D01 III
- Issued
- Jun 7, 2004
- Abate by
- Jul 23, 2004
Recent events (2)
- · I (O)
- · Z (O)
1910.134 E01
- Issued
- Jun 7, 2004
- Abate by
- Jul 23, 2004
Recent events (2)
- · I (O)
- · Z (O)
1910.134 F01
- Issued
- Jun 7, 2004
- Abate by
- Jul 23, 2004
Recent events (2)
- · I (O)
- · Z (O)
1910.134 K01 I
- Issued
- Jun 7, 2004
- Abate by
- Jul 23, 2004
Recent events (2)
- · I (O)
- · Z (O)
More inspections at Golden Eagle Cabinet Shop, INC.
View Golden Eagle Cabinet Shop, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337110)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 306438490.