Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: FANSTEEL AMERICAN SINTERED TECHNOLOGIES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FANSTEEL AMERICAN SINTERED TECHNOLOGIES in 513 EAST 2ND STREET, EMPORIUM, PA 15834 (NAICS 332117). OSHA activity number 306457037.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fansteel American Sintered Technologies — free Get an email when a new federal OSHA severe-injury report for Fansteel American Sintered Technologies is published. One employer, no account, unsubscribe in one click.
Site address
513 EAST 2ND STREET
City
EMPORIUM
State
PA
ZIP
15834
Mailing
P.O. BOX 149, EMPORIUM, PA 15834
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332117
SIC code (legacy)
3499
Employees
68
Ownership type
A

16 citations on file for this inspection.

5(a)(1)

Serious Gravity 05 8 instances 2 exposed
Issued
May 11, 2005
Abate by
Sep 1, 2005
Penalty
Initial $3,150 · Current $1,750 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to crushing and amputation injuries during the operation of
powdered metal (P/M)
presses provided with inadequate barrier guards, improperly adjusted
interlocks, and/or readily
removable fasteners:
a) Production Area - Gasbarre P/M molding press #S1, full revolution,
serial #88297,
40 ton, interlocked barrier guard was not installed. The interlock safety
device was
bypassed in the setup mode. Access at the front of the press was measured
at twelve
inches (12") wide x twelve inches (12") height and within eight inches
(8") of the point
of operation.
b) Production Area - Gasbarre P/M molding press #S2, full revolution,
serial #91450,
60 ton, interlocked barrier guard was not installed. The interlock safety
device was
bypassed in the setup mode. Access at the front of the press was measured
at twelve
inches (12") wide x twelve inches (12") height and within eight inches
(8") of the point
of operation.
c) Production Area - Gasbarre P/M molding press #S3, full revolution,
serial #96754,
45 ton, interlocked barrier guard was not installed. The interlock safety
device was
bypassed in the setup mode. Access at the front of the press was measured
at twelve
inches (12") wide x twelve inches (12") height and within eight inches
(8") of the point
of operation.
d) Production Area - Gasbarre P/M molding press #M1, part revolution,
serial #88296,
45 ton, had no barrier guard to protect an front opening on the adjustable
barrier guard
two inches (2") wide x six inches (6") long and ten inches (10") from the
point of
operation.
e) Production Area - Gasbarre P/M molding press #M11, part revolution,
serial #93519,
30 ton, had an front opening on the adjustable barrier guard two inches
(2") wide x five
inches (5") long and ten inches (10") from the point of operation.
f) Production Area - Gasbarre P/M molding press #M16, part revolution,
serial #94589,
200 ton, had an front opening on the adjustable barrier guard three inches
(3") wide x
eight inches (8") long and thirteen inches (13") from the point of
operation.
g) Production Area - Gasbarre P/M molding press #M18, part revolution,
serial #95659,
60 ton, had an front opening on the adjustable barrier guard two inches
(2") wide x six
inches (6") long and eleven inches (11") from the point of operation.
h) Production Area - Gasbarre P/M molding press #M21, part revolution,
serial #9889,
200 ton, had a front opening on the adjustable barrier guard fifteen
inches (15") wide x
thirty one inches (31") long and thirteen inches (13") from the point of
operation.
FEASIBLE ABATEMENT METHODS:
1. Utilize a fixed barrier guard to prevent entry of hands into the point
of operation by
reaching through, over, under, or around the guard and remove readily
removable
fasteners in accordance with ANSI B11.16-2003, section 8.4, Point of
Operation
Guards.
2. Secure and mount the barrier guard to minimize the possibility of
misuse or
unauthorized removal in accordance with ANSI B11.16-2003, section 8.3,
Guards.
Recent events (2)
  • — I (S) $1750.00
  • — Z (S) $3150.00

1910.138 A

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
Jun 1, 2005
Penalty
Initial $1,800 · Current $750 Reduced
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1800.00

1910.335 A02 I

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
Jun 1, 2005

1910.147 C04 II

Serious Gravity 05 1 instance 2 exposed
Issued
May 11, 2005
Abate by
Jun 15, 2005
Penalty
Initial $3,150 · Current $1,750 Reduced
Recent events (2)
  • — I (S) $1750.00
  • — Z (S) $3150.00

1910.151 C

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
Jun 15, 2005
Penalty
Initial $1,800 · Current $750 Reduced
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1800.00

1910.184 E01

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
May 16, 2005
Penalty
Initial $1,800 · Current $750 Reduced
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1800.00

1910.184 D

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
May 16, 2005

1910.184 E02 II

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
May 16, 2005

1910.184 I09 III

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
May 16, 2005

1910.212 A01

Serious Gravity 05 1 instance 2 exposed
Issued
May 11, 2005
Abate by
Sep 1, 2005
Penalty
Initial $3,150 · Current $1,750 Reduced
Recent events (2)
  • — I (S) $1750.00
  • — Z (S) $3150.00

1910.219 D01

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
May 16, 2005

1910.219 E01 I

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
May 16, 2005

1910.253 B04 III

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
May 16, 2005
Penalty
Initial $1,800 · Current $750 Reduced
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1800.00

1910.252 B02 IIG

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
Jun 1, 2005

1910.253 B02 II

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
May 16, 2005

1910.303 B02

Serious Gravity 02 1 instance 2 exposed
Issued
May 11, 2005
Abate by
Jun 1, 2005
Penalty
Initial $1,800 · Current $750 Reduced
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1800.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306457037.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.