Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: REGENEX CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of REGENEX CORPORATION in ONE NEW STREET, WEST MIDDLESEX, PA 16159 (NAICS 326199). OSHA activity number 306459983.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Regenex Corporation — free Get an email when a new federal OSHA severe-injury report for Regenex Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
REGENEX CORPORATION
Site address
ONE NEW STREET
City
WEST MIDDLESEX
State
PA
ZIP
16159
Mailing
P.O. BOX 608, WEST MIDDLESEX, PA 16159
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
SIC code (legacy)
3089
Employees
70
Ownership type
A

16 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 70 exposed
Issued
May 4, 2006
Abate by
Nov 1, 2006
Penalty
Initial $875 · Current $438 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employmnent and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that:
A.) REGENEX Corporation/Resale Process Systems & In House Process Systems:
Employees were potentially exposed to dust explosion hazards and related
burn injuries
because an evaluation was not conducted to determine whether hazards
necessitated the
installation of approved devices to prevent, mitigate, and/or control
hazards associated
with the propagation of dust explosions, deflagrations, and flame fronts
through plant
equipment, machinery, air systems, and related duct work:
(1) In Both the Resale and In House Departments, a Process Hazard Analysis
(PHA) and Process Risk Assessment were not conducted to determine whether
process hazards necessitated the installation of approved devices such as
explosion
protection systems, interlocked rotary valves,deflagration vents,
automatic
fast
acting valve systems, flame front diverters, and chemical isolation
systems to
prevent, mitigate, and/or control dust explosion hazards and the hazards
associated with propagation of deflagrations, explosions, and flame fronts
through
equipment, machinery, air systems, and conveying systems.  The equipment,
machinery, and systems included but were not limited to the grinders,
Cumberland grinder, RETEC, cyclones, dust collection system & bag units,
duct
work associated with the dust collection systems and air systems, air
movement
devices (e.g. fans/blowers), and the sorter.
NFPA 654 - Standard for the Prevention of Fire and Dust Explosions from the
Manufacturing, Processing, and Handling of Combustible Particulate Solids-
Sections 4.2.1 through 4.2.3 and 7.1 through 7.1.1 states the following:
4.2.1 - The design of explosion safety provisions shall be based on a
process
hazard analysis of the facility, the process, and associated fire or
explosion
hazards.
4.2.2 - The results of the Process Hazard Analysis will be documented and
maintained for the life of the process.
4.2.3 - The process hazard analysis shall be reviewed and updated at least
every
5 years.
7.1 - Methods of explosion protection for specific equipment.
7.1.1 - A documented risk evaluation acceptable to the authority having
jurisdiction shall be permitted to be conducted to determine the level of
protection
to be provided.
B.) REGENEX Corporation/Resale Process Systems & In House Process Systems:
Employees were potentially exposed to dust explosion hazards and related
burn injuries
because approved devices were not installed to prevent, mitigate, and/or
control the
hazards associated with the propagation of dust explosions, deflagrations,
and flame
fronts through plant equipment, machinery, air systems, and related duct
work.  In both
the Resale and In-house Departments:
(1) Air material separators (e.g. dust collection systems & bag
units/cyclones)
were located inside the building and were not protected by explosion
protection
systems and isolation devices.
NFPA 654 - Standard for the Prevention of Fire and Dust Explosions from the
Manufacturing, Processing, and Handling of Combustible Particulate Solids-
Section 7.13.1.1.1 states where an explosion hazard exists air material
separators
shall be located outside of buildings (Exception: Section 7.13.1.1.2(1)
Unless the
air material separator is protected by an explosion protection system)
Section 7.13.1.5 & 7.1.4 - Where an explosion hazard exists, isolation
devices
shall be provided for air material separators.
(2) Deflagration isolation devices were not installed between
interconnected pieces
of equipment
NFPA 654 - Standard for the Prevention of Fire and Dust Explosions from the
Manufacturing, Processing, and Handling of Combustible Particulate Solids:
Section 7.1.4.1 states where an explosion hazard exists, isolation devices
shall be
provided to prevent deflagration propagation between pieces of equipment
connected by duct work.
(3) Grinders in the In-house Department and the  Cumberland Grinder and
RETEC in the Resale Department were not equipped with an explosion
protection
system.
NFPA 654 - Standard for the Prevention of Fire and Dust Explosions from the
Manufacturing, Processing, and Handling of Combustible Particulate Solids:
Section A7.15 - Size reduction machinery includes equipment such as mills,
grinders, and pulverizers.
Section 7.15.2 & 7.1.2 states where an explosion hazard exists, an
explosion
protection system shall be provided on size reduction machinery
ABATEMENT NOTE:
Among other methods, feasible and acceptable means to correct the
conditions noted in
Instances A and B above include:
(1) Instance A = Complying with the applicable requirements noted in NFPA
654 -
Standard for the Prevent of Fire and Dust Explosions from the
Manufacturing,
Processing, and Handling of Combustible Particulate Solids- by conducting
a PHA &Process Risk Assessment.  The PHA/Process Risk Assessment must be
documented and
kept on file.
(2) Instance B/Air-Material Separators = Relocate the air material
separators (e.g.
cyclones, dust collection systems & bag units to the exterior of the
building.  And/or,
install approved deflagration devices, isolation devices, and explosion
protection systems
in in accordance with the PHA/Risk Assessment and the requirements noted
in NFPA
654.
(3) Instance B/Deflagration Isolation Devices, Grinders, and RETEC =
Install
approved deflagration devices, isolation devices, and explosion protection
systems in
accordance with the PHA/Risk Assessment and the requirements noted in NFPA
654.
C.) REGENEX Corporation/Resale Department/West Wall By Exit Door/Gas Fired
Heater Suspended Above the Floor:  Employees were potentially exposed to
dust
explosion hazards and related burn injuries from potential ignition
sources which included
but were not limited to gas fired heaters that were located in a process
area/environment
that generated and transported explosive plastic dust.  In the Resale
Department, the gas
fired heater was located in the same area as the Resale process line and
its related
equipment which generated/transported explosive plastic dust.
NFPA 654 - Standard for the Prevent of Fire and Dust Explosions from the
Manufacturing, Processing, and Handling of Combustible Particulate Solids-
Sections 9.6.1 through 9.6.3 states the following: 9.6.1 In areas
processing
combustible
dusts, process and comfort heat shall be provided by indirect means.
9.6.2 Fired
equipment shall be located outdoors on in a separate dust-free room or
building 9.6.3 Air
for combustion shall be taken from a clean outside source 9.6.4 Comfort
air systems for
processing areas contain combustible dusts shall not be recirculated.
ABATEMENT NOTE:
Among other methods, feasible and acceptable means to correct the
conditions noted with
the gas fired heater include:
(1) Complying with the applicable requirements noted in NFPA 654 -
Standard for the
Prevent of Fire and Dust Explosions from the Manufacturing, Processing,
and Handling
of Combustible Particulate Solids- Sections 9.6.1 through 9.6.6
(2) Relocate the gas fired heater to a separate dust free room, area,  or
building and
transfer the heat via indirect means through the duct work.
Recent events (2)
  • — I (S) $438.00
  • — Z (S) $875.00

1910.22 A01

Serious Gravity 03 1 instance 70 exposed
Issued
May 4, 2006
Abate by
Nov 1, 2006
Penalty
Initial $875 · Current $437 Reduced
Recent events (2)
  • — I (S) $437.00
  • — Z (S) $875.00

1910.1200 H02 II

Serious Gravity 03 1 instance 70 exposed
Issued
May 4, 2006
Abate by
Nov 1, 2006
Recent events (2)
  • — I (S)
  • — Z (S)

1910.23 C01

Serious Gravity 02 3 instances 3 exposed
Issued
May 4, 2006
Abate by
Jul 13, 2006
Penalty
Initial $700 · Current $300 Reduced
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $700.00

1910.23 A08

Serious Gravity 01 1 instance 3 exposed
Issued
May 4, 2006
Abate by
Jul 13, 2006

1910.176 B

Serious Gravity 02 12 instances 10 exposed
Issued
May 4, 2006
Abate by
Jul 13, 2006
Penalty
Initial $700 · Current $300 Reduced
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $700.00

1910.176 A

Serious Gravity 02 1 instance 10 exposed
Issued
May 4, 2006
Abate by
Jul 13, 2006

1910.212 A01

Serious Gravity 02 3 instances 10 exposed
Issued
May 4, 2006
Abate by
Jul 13, 2006
Penalty
Initial $700 · Current $300 Reduced
Recent events (2)
  • — I (S) $300.00
  • — Z (S) $700.00

1910.219 C02 I

Serious Gravity 02 1 instance 8 exposed
Issued
May 4, 2006
Abate by
Jul 13, 2006

1910.215 A04

Serious Gravity 01 1 instance 3 exposed
Issued
May 4, 2006
Abate by
May 9, 2006
Penalty
Initial $446 · Current $223 Reduced
Recent events (2)
  • — I (S) $223.00
  • — Z (S) $446.00

1910.215 B09

Serious Gravity 01 1 instance 3 exposed
Issued
May 4, 2006
Abate by
May 9, 2006

1910.253 B04 III

Serious Gravity 01 1 instance 2 exposed
Issued
May 4, 2006
Abate by
May 9, 2006
Penalty
Initial $446 · Current $223 Reduced
Recent events (2)
  • — I (S) $223.00
  • — Z (S) $446.00

1910.303 B01 II

Serious Gravity 01 1 instance 9 exposed
Issued
May 4, 2006
Abate by
Jul 13, 2006
Penalty
Initial $525 · Current $413 Reduced
Recent events (2)
  • — I (S) $413.00
  • — Z (S) $525.00

1910.305 B01

Serious Gravity 01 1 instance 9 exposed
Issued
May 4, 2006
Abate by
Jul 13, 2006

1910.303 G02 I

Serious Gravity 03 1 instance 3 exposed
Issued
May 4, 2006
Abate by
Jul 13, 2006
Penalty
Initial $875 · Current $437 Reduced
Recent events (2)
  • — I (S) $437.00
  • — Z (S) $875.00

1910.333 C02

Serious Gravity 03 1 instance 3 exposed
Issued
May 4, 2006
Abate by
Jul 6, 2006

View Regenex Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306459983.