PATERSON, NJ —
OSHA Inspection: UNITED SCRAP IRON & METAL, INC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of UNITED SCRAP IRON & METAL, INC in 157 EAST 7TH STREET, PATERSON, NJ 07509 (NAICS 423930). OSHA activity number 306555590.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED SCRAP IRON & METAL, INC
- Site address
- 157 EAST 7TH STREET
- City
- PATERSON
- State
- NJ
- ZIP
- 07509
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- SIC code (legacy)
- 5093
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 25, 2004
- Abate by
- May 11, 2004
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion of a compressed gas cylinder: a)Scrap Yard: Employees involved in a scrap metal operation were exposed to the hazards of explosion in that procedures to identify and isolate compressed gas cylinders prior to disposal were not implemented to a degree which would insure mishaps would not occur as specified in Compressed Gas Association Pamphlet C-2 sections 1.3, 1.6, 2.0 and 3.1., on or about November 5, 2003. Among other methods feasible means of abatement include: 1.All cylinders and/or pressurized containers must be placed in a separate location apart from other scrap and safely handled. 2.Ensure that employees are trained on the Compressed Gas Association Pamphlet C-2.hlet
1910.212 A03 II
- Issued
- Mar 25, 2004
- Abate by
- May 11, 2004
More inspections in this industry (NAICS 423930)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306555590.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.