OSHA Inspection: POLYMER PRODUCTS CO., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of POLYMER PRODUCTS CO., INC. in 100 STATION AVE, STOCKERTOWN, PA 18083 (NAICS 326121). OSHA activity number 306579483.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Polymer Products CO., INC. — free Get an email when a new federal OSHA severe-injury report for Polymer Products CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 STATION AVE
City
STOCKERTOWN
State
PA
ZIP
18083
Mailing
PO BOX 98, STOCKERTOWN, PA 18083
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326121
SIC code (legacy)
3089
Employees
45
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 29, 2004
Abate by
Mar 29, 2004
Penalty
Initial $2,500 · Current $2,000 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to a fire and explosion hazards where an indoor gas hose and
connector were
concealed and not kept tight:
a)  Quality Control Lab - A concealed connector (worm clamp) came loose
from Tygon
tubing causing it to disconnect from the piping system and leak methane
gas.  Unable to
see the indoor gas hose connector had disconnected from the Bunsen burner,
an employee
used a starter to light the burner and a flash occurred and caused the
employee to suffer
burns, on or about 1/9/04.
ABATEMENT:  Among other methods, one feasible and acceptable abatement
method
to correct this hazard is to have the connections to piping, regulators,
and
other
appliances always in the open and kept tight to prevent leakage.   NFPA
54-5.5.2(a) -
Indoor gas hose connectors shall not be concealed.
No abatement certification or documentation required.
Recent events (2)
  • — I (S) $2000.00
  • — Z (S) $2500.00

1910.138 B

Other-than-serious Gravity 05 1 instance 3 exposed
Issued
Mar 29, 2004
Abate by
Mar 29, 2004
Penalty
Initial $1,225
Recent events (2)
  • — I (O)
  • — Z (S) $1225.00

View Polymer Products CO., INC.'s full OSHA safety record →