Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WILCO WELDING & REPAIR, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of WILCO WELDING & REPAIR, INC. in 2311 WILCO BLVD., WILSON, NC 27893 (NAICS 811310). OSHA activity number 306590936.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wilco Welding & Repair, INC. — free Get an email when a new federal OSHA severe-injury report for Wilco Welding & Repair, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2311 WILCO BLVD.
City
WILSON
State
NC
ZIP
27893
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
SIC code (legacy)
7692
Employees
5
Ownership type
A
Industry flags
Manufacturing safety.

54 citations on file for this inspection.

95012901

Serious 4 instances 4 exposed
Issued
Aug 25, 2003
Abate by
Oct 10, 2003
Penalty
Initial $1,050 · Current $500 Reduced
North Carolina General Statute 95-129(1) of the Occupational
Safety and Health Act of North Carolina: The employer did not
furnish to each of his employees conditions of employment and a
place of employment free from recognized hazards that were
causing or likely to cause death or serious physical harm to
employees, in that employees were exposed to: (Reference:
American Society of Mechanical Engineers ASME B30.16-1998)
a)Facility - employees were allowed to lift truck bodies
weighing as much as 5000 pounds using a combination of
mechanical (hand chain) hoists and electrical (wire
rope) and/or chain hoists that (all) had not been
subjected to frequent (monthly) or periodic (yearly)
inspections. (Reference : ASME B30.16-1998, paragraph
16-2.1.1)
b)Facility - employees were allowed to lift truck bodies
weighing as much as 5000 pounds using a combination of
mechanical (hand chain) hoists and electrical (wire
rope) and/or chain hoists that were (all) missing the
safety latch from the load hooks. (Reference: ASME
B30.16-1998, paragraph 16-1.2.9
c)Facility - employees were allowed to lift truck bodies
weighing as much as 5000 pounds using a combination of
mechanical (hand chain) hoists and electrical (wire
rope) and/or chain hoists with unknown capacities (none
of the hoist capacities could be read and/or determined
from the ground). (Reference: ASME B30.16-1998,
paragraph 16-1.1.1)
d)Facility - employees were allowed to lift truck bodies
weighing as much as 5000 pounds using a combination of
mechanical (hand chain) hoists and electrical (wire
rope) and/or chain hoists with none of the required
warnings posted.(Reference: ASME B30.16-1998,
paragraph 16-1.1.4)
Among other methods, some feasible and acceptable abatement
methods to correct this hazard would be to institute a
regular inspection program to identify and correct hoist
deficiencies as they occur and to remove hoists from service
as needed.
Recent events (2)
  • — I (S) $500.00
  • — Z (S) $1050.00

95012901

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Penalty
Initial $2,100 · Current $2,100
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North
Carolina: The employer did not furnish to each of his employees conditions
of employment and a
place of employment free from recognized hazards that were causing or
likely to cause death or
serious physical harm to employees, in that employees were exposed to:
(Reference: American
National Standard ANSI/ASC Z49.1-1988)
a)Facility - employees were allowed to perform arc welding inside a five
foot
diameter stainless steel tank without the benefit of personal protective
equipment
(PPE) or protective devices to prevent accidental contact with the
positive lead of
the welder, and simultaneous contact with the tank, which would act as
ground,
and created the potential of electrocution. Additional factors creating an
electrocution probability was extremely hot conditions inside the tank,
ideal for
profuse perspiration, as well as the presence of a shallow layer of water
in the
bottom of the tank. (Reference: ANSI/ASC Z49.1-1988, paragraph 11.2.2 and
11.4.9.2; NIOSH publication 77-131; American Welding Society Pamphlet dated
1988, titled ARC Welding Safety; American Federation of State, County and
Municipal Employees (AFL-CIO) Fact Sheet, Health and Safety: Welding
Hazards)
Among other methods, some feasible and acceptable abatement methods to
correct this hazard would be to use mechanical ventilation (to cool the
area
and
evaporate moisture, in addition to PPE and protective equipment such as
rubber
gloves, and a rubber mat on which to stand/kneel.
Recent events (2)
  • — I (S) $2100.00
  • — Z (S) $2100.00

1910.22 A01

Serious 1 instance 4 exposed
Issued
Aug 25, 2003
Abate by
Oct 10, 2003
Penalty
Initial $225 · Current $100 Reduced
Recent events (2)
  • — I (S) $100.00
  • — Z (S) $225.00

1910.22 D01

Serious 1 instance 3 exposed
Issued
Aug 25, 2003
Abate by
Oct 10, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 C01

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Penalty
Initial $2,100 · Current $2,100
Recent events (2)
  • — I (S) $2100.00
  • — Z (S) $2100.00

1910.146 C02

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 C04

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 C09 I

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 D02

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 D03

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 D04

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 D05 I

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 D05 II

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 D09

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 E01

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 G01

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 H01

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.146 K04

Serious 1 instance 1 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.147 C01

Serious 1 instance 4 exposed
Issued
Aug 25, 2003
Abate by
Oct 10, 2003
Penalty
Initial $1,050
Recent events (2)
  • — I (S)
  • — Z (S) $1050.00

1910.184 D

Serious 1 instance 3 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Penalty
Initial $1,050
Recent events (2)
  • — I (S)
  • — Z (S) $1050.00

1910.184 E01

Serious 1 instance 3 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.184 E03 I

Serious 1 instance 3 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.184 E04

Serious 1 instance 3 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.212 A01

Serious 4 instances 3 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Penalty
Initial $1,050 · Current $750 Reduced
Recent events (2)
  • — I (S) $750.00
  • — Z (S) $1050.00

1910.219 B01

Serious 2 instances 3 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.215 A04

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Penalty
Initial $750
Recent events (2)
  • — I (S)
  • — Z (S) $750.00

1910.215 B09

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.252 A03 I

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Penalty
Initial $2,100 · Current $2,100
Recent events (2)
  • — I (S) $2100.00
  • — Z (S) $2100.00

1910.252 B02 III

Serious 1 instance 1 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.252 B04 IV

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.252 B04 IV

Serious 1 instance 1 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.252 C02 IA

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.254 D09 III

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003

1910.303 B01

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Penalty
Initial $2,100 · Current $2,100
Recent events (2)
  • — I (S) $2100.00
  • — Z (S) $2100.00

1910.303 B02

Serious 1 instance 3 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.303 F

Serious 1 instance 3 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.303 G01 I

Serious 1 instance 3 exposed
Issued
Aug 25, 2003
Abate by
Aug 28, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.304 F04

Serious 2 instances 1 exposed
Issued
Aug 25, 2003
Abate by
Aug 28, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 A02 IIIG

Serious 1 instance 1 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 B01

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 B02

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 B02

Serious 2 instances 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 G01 III

Serious 1 instance 1 exposed
Issued
Aug 25, 2003
Abate by
Aug 28, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 G02 II

Serious 1 instance 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.305 G02 III

Serious 3 instances 2 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.334 A02 I

Serious 1 instance 3 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.334 A02 II

Serious 1 instance 4 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.335 A01 I

Serious 1 instance 1 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003
Recent events (2)
  • — I (S)
  • — Z (S)

1910.23 D01 IV

Other-than-serious 1 instance 1 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003

1910.132 D01

Other-than-serious 1 instance 4 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003

1910.157 E02

Other-than-serious 1 instance 3 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003

1910.157 E03

Other-than-serious 1 instance 3 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003

1910.157 G01

Other-than-serious 1 instance 3 exposed
Issued
Aug 25, 2003
Abate by
Sep 19, 2003

1910.178 L01 I

Other-than-serious 1 instance 1 exposed
Issued
Aug 25, 2003
Abate by
Oct 10, 2003

View Wilco Welding & Repair, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306590936.