Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KOSA

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KOSA in 4600 US HWY. 421 N., WILMINGTON, NC 28401 (NAICS 325211). OSHA activity number 306593534.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kosa — free Get an email when a new federal OSHA severe-injury report for Kosa is published. One employer, no account, unsubscribe in one click.
Establishment
KOSA
Site address
4600 US HWY. 421 N.
City
WILMINGTON
State
NC
ZIP
28401
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
SIC code (legacy)
2821
Employees
500
Ownership type
A
Industry flags
Manufacturing safety.

5 citations on file for this inspection.

95012901

Serious 1 instance 7 exposed
Issued
Feb 12, 2004
Abate by
Mar 31, 2004
Penalty
Initial $3,850 · Current $3,850
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina: The
employer did not furnish each of his employees conditions of employment
and a place of employment free from
recognized hazards that were causing or likely to cause death or serious
physical harm to employees in that employees
were exposed to: emergency venting of steam and condensate.
a)facility, near Boiler #1 - Employees were exposed to an over
pressurization of the A/B Letdown station
and subsequent release of steam and condensate.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to
establish a preventative maintenance program to insure that all monitoring
devices are functional and
calibrated.
Recent events (2)
  • — I (S) $3850.00
  • — Z (S) $3850.00

95012901

Serious 1 instance 7 exposed
Issued
Feb 12, 2004
Abate by
Mar 31, 2004
Penalty
Initial $3,850
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina: The
employer did not furnish each of his employees conditions of employment
and a place of employment free from
recognized hazards that were causing or likely to cause death or serious
physical harm to employees in that employees
were exposed to: emergency discharge of steam and condensate.
a)facility, near Boiler #1 - Employees were exposed to hazards associated
with pressure relief capacity
that was not sufficient on the vertical discharge stack on or about August
19th 2003, which caused a
release of condensate and steam.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to re-size the discharge piping on the pressure
relief vavles.
Reference: 13 NCAC 7A Chapter 13, Title 13, section 0.0405(e)
Reference: ASME B31.3-2002. Sect 322.6.3: The required relieving capacity
of any pressure relieving device did not
include consideration of all piping systems which it protected.
Recent events (2)
  • — I (S)
  • — Z (S) $3850.00

95012901

Serious 1 instance 7 exposed
Issued
Feb 12, 2004
Abate by
Mar 31, 2004
Penalty
Initial $3,850
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina: The
employer did not furnish to each of his employees conditions of employment
and a place of employment free from
recognized hazards that were causing or likely to cause death or serious
physical harm to employees, in that employees
were exposed to: emergency steam release from pressure relief valves.
a)facility, near boiler #1 - an 18 inch gap existed in the vertical
discharge stack which allowed steam and
condensate to discharge 4 feet above grade, and 6 feet below an area where
employees were working.
b)facility, near boiler #1 - the fixed cap at the top of the vertical
discharge stack was corroded which
would allow condensate and steam to exit the pipe and travel towards the
ground where employees
were working.
c)facility, near boiler #1 - the discharge from the vertical stack was not
a safe distance from the work
platform where employees were working.
Among other methods one feasible and acceptable abatement method to
correct this hazard is to insure
the components within the piping system are interconnected with no gaps,
and to insure that all
components are not subjected to corrosion, and that all discharge stacks
be directed away from
employee work areas.
Reference: 13 NCAC 7A Chapter 13, Title 13, section 0.405(h).
Reference: ASME B31.3-2002, section 322.6.2
Recent events (2)
  • — I (S)
  • — Z (S) $3850.00

95012901

Serious 1 instance 7 exposed
Issued
Feb 12, 2004
Abate by
Mar 31, 2004
Penalty
Initial $3,850
North Carolina General Statute 95-129(1) of the Occupational Safety and
Health Act of North Carolina: The
employer did not furnish to each of his employees conditions of employment
and a place of employment free from
recognized hazards that were causing or likely to cause death or serious
physical harm to employees, in that employees
were exposed to: emergency discharge of steam and condensate.
a)facility, near boiler #1 - Employees were exposed to hazards associated
with
drip pan drains that were
corroded and not working on the discharge stack on the A/B let down line.
This resulted in the build up
of condensate within the stack which discharged on or about Aug 18.
Among other methods, one feasible and acceptable method is to redesign the
drip pans and insure they
are not corroded, to allow for drainage of the condensate.
Reference: 13 NCAC 7A Chapter 13, Title 13, Sect 0.0405(h)
Reference ASME B31.3-2002
Recent events (2)
  • — I (S)
  • — Z (S) $3850.00

1910.147 F02 I

Deleted Serious 1 instance 7 exposed
Issued
Feb 12, 2004
Abate by
Mar 31, 2004
Penalty
Initial $3,850 · Current $3,850
Recent events (2)
  • — I (S) $3850.00
  • — Z (S) $3850.00

View Kosa's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306593534.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.