PONCE, PR —
OSHA Inspection: PR STEEL PRODUCTS CORP
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PR STEEL PRODUCTS CORP in EL TUQUE INSDUTRIAL PARK, PONCE, PR 00728 (NAICS 331221). OSHA activity number 306662222.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PR STEEL PRODUCTS CORP
- Site address
- EL TUQUE INSDUTRIAL PARK
- City
- PONCE
- State
- PR
- ZIP
- 00728
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331221
- SIC code (legacy)
- 3312
- Employees
- 5
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
3 citations on file for this inspection.
6A0001
- Issued
- Jan 20, 2004
- Abate by
- Jan 28, 2004
- Penalty
- Initial $450 · Current $225 Reduced
General-duty citation text
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: a. Receive injuries do to poor quality of illumination(100 F. C.) In different job area, the quantity of ilumination (the amount of ilumination that produces luminance for the task and surrounding), is inadecuate. According to the A.N.S.I.A11.1-1973, Sec.2.2.1, lighting instalations should be designed by a competend iluminating engeneer. Among other methods, one feasible and acceptable abatement methods to correct this hazard is the instalation of an additinal new lighting source. Hazard: Accidents due to poor ilumination. a. Recibir heridas debido a una pobre calidad de iluminacion (100 f. C.). En distintas areas de trabajo, cantidad de iluminacion producida por las iluminarias y los alrededores) es inadecuada. De acuerdo con el A.N.S.I. A 11.1-1973, Sec.2.2.1, las instalaciones de luz deben ser hechas por un ingeniero de iluminacion competente. Entre otros metodos, un metodo aceptable y posible para corregir este riesgo es mediante la instalacion de nuevas fuentes de luz (focos potentes). Riesgo. Accidentes debido a pobre iluminacion.
Recent events (2)
- — I (S) $225.00
- — Z (S) $450.00
1910.22 A02
- Issued
- Jan 20, 2004
- Abate by
- Jan 28, 2004
- Penalty
- Initial $450 · Current $225 Reduced
Recent events (2)
- — I (S) $225.00
- — Z (S) $450.00
1910.22 B02
- Issued
- Jan 20, 2004
- Abate by
- Jan 28, 2004
- Penalty
- Initial $450 · Current $225 Reduced
Recent events (2)
- — I (S) $225.00
- — Z (S) $450.00
More inspections at PR Steel Products Corp
View PR Steel Products Corp's full OSHA safety record →
More inspections in this industry (NAICS 331221)
More inspections in PR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306662222.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.