OSHA Inspection: P.M. ARMOR, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of P.M. ARMOR, INC. in 237 E PROSPECT AVE., MT.PROSPECT, IL 60056 (NAICS 332710). OSHA activity number 306717281.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch P.M. Armor, INC. — free Get an email when a new federal OSHA severe-injury report for P.M. Armor, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
P.M. ARMOR, INC.
Site address
237 E PROSPECT AVE.
City
MT.PROSPECT
State
IL
ZIP
60056
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
332710
SIC code (legacy)
3599
Employees
20
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 03 2 instances 1 exposed
Issued
Jul 9, 2003
Abate by
Jul 28, 2003
Penalty
Initial $750 · Current $525 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to:
a)Shop Area-The Grob Inc vertical bandsaw type NS18/serial 10158 and the
Franz Haberle cold
saw Type HL4 model 92180783, were not equipped with  magnetic restarters
or similar devices,
as prescribed by American National Standards Institute (ANSI) B11.10-1990,
Section 5.2.3.4,
that in the event of an interruption in the electrical supply such a
device would prevent the saw
from restarting automatically when power is restored.
Abatement documentation is required for this item in accordance with the
requirements of
29 CFR 1903.19(d).s
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $750.00