OSHA Inspection: THE NORTHWESTERN CORPORATION

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of THE NORTHWESTERN CORPORATION in 922 ARMSTRONG STREET, MORRIS, IL 60450 (NAICS 333311). OSHA activity number 306722885.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Northwestern Corporation — free Get an email when a new federal OSHA severe-injury report for The Northwestern Corporation is published. One employer, no account, unsubscribe in one click.
Site address
922 ARMSTRONG STREET
City
MORRIS
State
IL
ZIP
60450
Mailing
P.O. BOX490, MORRIS, IL 60450
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333311
SIC code (legacy)
3581
Employees
38
Ownership type
A
Industry flags
Manufacturing health.

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 3 instances 3 exposed
Issued
Dec 29, 2004
Abate by
Jan 31, 2005
Penalty
Initial $875 · Current $613 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
a place of employment which was free from recognized hazards that were
likely to cause death
or serious physical harm to employees in that employees were not protected
from automatic
restart of metal-cutting saws:  The following saws did not have magnetic
restart provisions:
a) Kalamazoo Band Saw 824D, serial #18L39, in the Tool Room; b) DoAll
Contour 16" Saw
1613-2, serial #150-60156, in the Tool Room; and c) Enco 360 Band Saw,
mfg. #36577, in the
Injection Molding Area (Plastics Area).  ANSI B11.10 (1990), Section
4.2.3.4 states that "in
the event of an interruption in the electrical power supply, the machine
shall not restart
automatically when power is restored".  A feasible means of abatement
would be to install a
motor control device or magnetic restart to prevent automatic restart
after an interruption in the
power supply, as required by ANSI B11.10 (1974).  CERTIFICATION OF
ABATEMENT IS
REQUIRED FOR THESE ITEMS.
Recent events (2)
  • — I (S) $613.00
  • — Z (S) $875.00

1910.305 G02 III

Serious Gravity 02 2 instances 3 exposed
Issued
Dec 29, 2004
Abate by
Jan 18, 2005
Penalty
Initial $400 · Current $280 Reduced

Hazardous substances 8870

Recent events (2)
  • — I (S) $280.00
  • — Z (S) $400.00

View The Northwestern Corporation's full OSHA safety record →