LASALLE, IL ·
OSHA Inspection: TURK FURNITURE
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TURK FURNITURE in 2ND & JOLIET STS., LASALLE, IL 61301 (NAICS 442110). OSHA activity number 306726597.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TURK FURNITURE
- Site address
- 2ND & JOLIET STS.
- City
- LASALLE
- State
- IL
- ZIP
- 61301
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 442110
- SIC code (legacy)
- 5712
- Employees
- 10
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 13, 2004
- Abate by
- Oct 15, 2004
- Penalty
- Initial $2,500 · Current $1,250 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to fall hazards and crushing hazards due to absence of hoistway gate interlocks or locking devices, unguarded or partially guarded hoistway-landing openings, and absence of elevator car door: Turk Furniture, LaSalle store - the Otis freight elevator was not installed in accordance with the American National Standard for Elevators and Escalators (ASME A17.1-2000). Deficiencies include, but may not be limited to, the following sections: a. Hoistway gate(s) were not equipped with interlocks or mechanical locking devices, as required by Section 2.12, to prevent opening of the gate from the landing side unless the car is within the landing zone. b. Hoistway vertical sliding gates on the first, second, and third floors did not fully enclose the hoistway-landing openings as required by Section 2.11. The hoistway-landing opening at the basement level was not provided with an entrance. c. The elevator car was not equipped with a car door as required by Section 2.14. Feasible means of abatement include installation of gate interlocks, total enclosures of hoistway-landing openings, and installation of elevator car door per ASME A17.1-2000 Code requirements. DOCUMENTATION AND CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS ITEM.
Recent events (2)
- · I (S) $1250.00
- · Z (S) $2500.00
More inspections in this industry (NAICS 442110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306726597.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.