LAS VEGAS, NV ·
OSHA Inspection: SKINVISIBLE PHARMACEUTICALS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of SKINVISIBLE PHARMACEUTICALS, INC. in 6320 S SANDHILL ROAD, SUITE 10, LAS VEGAS, NV 89120 (NAICS 325412). OSHA activity number 306784430.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SKINVISIBLE PHARMACEUTICALS, INC.
- Site address
- 6320 S SANDHILL ROAD, SUITE 10
- City
- LAS VEGAS
- State
- NV
- ZIP
- 89120
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325412
- SIC code (legacy)
- 2834
- Employees
- 4
- Ownership type
- Private (A)
- Industry flags
- Manufacturing health.
Citations
10 citations on file for this inspection.
618037501
- Issued
- Aug 11, 2003
- Abate by
- Sep 13, 2003
- Penalty
- Initial $750 · Current $750
General-duty citation text
Nevada Revised Statute 618.375(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: a.Employee were exposed to injuries resulting from being struck by fragments of schedule 40 PVC pipe, used to distribute up to 90-100 psi of compressed air, which is not recommended by the manufacturer because of heat breakdown and potential fragmentation. One feasible method, among others, would be to replace the PVC pipe with a pipe capable of withstanding compressed air distribution. Reference: PVC manufacturers data caution and warning notices which state, "Do not use compressed air or gas for pressure testing", "PVC and CPVC products are not recommended for use in compressed air or gas systems", and "The manufacturer does not recommend its PVC or CPVC products for use in air or compressed gas systems. PVC and CPVC pipe, fittings, and valves are excellent products for the transport of water and corrosive chemicals. But there are a number of other piping products that are especially designed and suited for compressed air and gases", and finally, from Apache Plastics Company, the manufacturer in this case, "Do not use or test PVC pipe with compressed air or gas, as the sudden release of stored energy can result in a catastrophic failure."hic
618054201 C
- Issued
- Aug 11, 2003
- Abate by
- Sep 13, 2003
- Penalty
- Initial $300 · Current $300
1910.132 D02
- Issued
- Aug 11, 2003
- Abate by
- Sep 13, 2003
- Penalty
- Initial $150 · Current $150
1910.132 F01
- Issued
- Aug 11, 2003
- Abate by
- Sep 13, 2003
1910.134 C01
- Issued
- Aug 11, 2003
- Abate by
- Aug 14, 2003
1910.134 C02 I
- Issued
- Aug 11, 2003
- Abate by
- Aug 29, 2003
1910.1200 E01
- Issued
- Aug 11, 2003
- Abate by
- Sep 13, 2003
1910.1200 E01 I
- Issued
- Aug 11, 2003
- Abate by
- Aug 29, 2003
1910.1200 H02
- Issued
- Aug 11, 2003
- Abate by
- Sep 13, 2003
1910.1450 E01
- Issued
- Aug 11, 2003
- Abate by
- Sep 13, 2003