OSHA Inspection: APACHE STAINLESS EQUIPMENT CORP

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of APACHE STAINLESS EQUIPMENT CORP in 2910 APACHE DR., PLOVER, WI 54467 (NAICS 332420). OSHA activity number 306798869.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Apache Stainless Equipment Corp — free Get an email when a new federal OSHA severe-injury report for Apache Stainless Equipment Corp is published. One employer, no account, unsubscribe in one click.
Site address
2910 APACHE DR.
City
PLOVER
State
WI
ZIP
54467
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
SIC code (legacy)
3443
Employees
25
Ownership type
A

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 2 exposed
Issued
Jul 28, 2005
Abate by
Aug 30, 2005
Penalty
Initial $4,000 · Current $1,600 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazards of being struck by the force of sudden and
unexpected releases of
air pressure, and the water and parts propelled from the tank by that air
pressure following a
hydrostatic test of a pressure vessel where air pressure had been applied
to the tank in order to
drain it more rapidly.
Feasible methods to correct this hazard include, but are not limited to,
1)  Establishing a written procedure which addresses steps to be followed
for the safe dissipation
of stored energy, and especially where circumstances deviate from normal
hydrostatic or
pneumatic test procedures.
2)  Ensure that all sources for re-introduction of energy to the tank are
controlled in order to
prevent re-introduction of pressure when unknown to the operator.
3)  Train employees on these practices and procedures in the performance
of hydrostatic or
pneumatic test.
Abatement Certification and Abatement Documentation required.
Recent events (2)
  • — I (S) $1600.00
  • — Z (S) $4000.00

1910.147 C06 I

Deleted Serious Gravity 03 2 instances 2 exposed
Issued
Jul 28, 2005
Abate by
Aug 30, 2005
29 CFR 1910.147(c)(6)(i):  The employer did not conduct an annual or more
frequent inspection
of the energy control procedure to ensure that the procedure and
requirements of this standard
were followed:
a) Periodic inspection of the energy control procedures had not been
conducted since 2000.
b) Periodic inspection of the hydrostatic and pneumatic tank testing and
inspection procedures
had not been conducted.
Abatement Certification and Abatement Documentation required.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.147 D

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Jul 28, 2005
Abate by
Aug 1, 2005
29 CFR 1910.147(d):  The established procedure for the application of
energy control (the
lockout or tagout procedures) did not cover the following elements,
actions and done in sequence
as required by 29 CFR 1910.147 (d)(1) (d)(6):
a) The hydrostatic test procedures did not require, nor was a lock-out or
tag-out device, or any
other acceptable means of isolation of energy (preventing unexpected
re-introduction of air, or
over-pressuring by compressed air or water) used on the tank or air line
to the tank undergoing
a hydrostatic test procedure on 3/4/05.  Air pressure was applied through
an air line to the tank
to assist in the tank draining.  Paragraph (d)(4)(i) requires "Lock-out or
tag-out devices shall be
affixed to each energy isolating device by authorized employees."
b) The hydrostatic or pneumatic test procedures did not address, nor was
the stored air pressure
fully dissipated from the tank being drained following a hydrostatic test
on
3/4/05 prior to an
employee opening the tank. Paragraph (d)(5)(i) requires "All potentially
hazardous stored or
residual energy be relieved, disconnected, restrained or otherwise
rendered safe after the
application of lockout or tagout devices to energy isolating device"
Abatement Certification and Abatement Documentation required.
Recent events (2)
  • — I (S)
  • — Z (S)

1910.1030 C01 I

Serious Gravity 03 1 instance 1 exposed
Issued
Jul 28, 2005
Abate by
Aug 30, 2005
Penalty
Initial $1,625 · Current $650 Reduced
Recent events (2)
  • — I (S) $650.00
  • — Z (S) $1625.00

View Apache Stainless Equipment Corp's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306798869.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.