Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALBENESE D&S INCORPORATED

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ALBENESE D&S INCORPORATED in PARK STREET, ATTLEBORO, MA 02703 (NAICS 237110). OSHA activity number 306807975.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Albenese D&S Incorporated — free Get an email when a new federal OSHA severe-injury report for Albenese D&S Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
PARK STREET
City
ATTLEBORO
State
MA
ZIP
02703
Mailing
66 SILVA LANE, DRACUT, MA 01826
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
237110
SIC code (legacy)
1623
Employees
44
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 1 exposed
Issued
Nov 4, 2003
Abate by
Nov 17, 2003
Penalty
Initial $2,500 · Current $1,250 Reduced
Section 5(a)(1) of the occupational safety and health act of 1970:  The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that the employees
were exposed to electrical shock and/or burn hazards in the event that the
cut trees and/or tree
branches under the electrical power lines which were not adequately
secured were to be
displaced allowing the power line(s) to fall and come into contact with
either the excavation
equipment and/or employees:
Location:  Job site.
The employees exposed to the hazards of electrical shock and burns when
branches were used as a "Service Mast" to raise the service drops over the
work
area.  The branches were installed by unqualified employees and were not
supported, guyed, or of adequate strength as required bt the National
Electrical
Code Article 230.28 to prevent them from falling to the ground and/or
equipment
below.
Among other methods one feasible and acceptable abatement method would be
to
contact the power company to have the electrical power lines removed or
adjusted.l
Recent events (2)
  • — I (S) $1250.00
  • — Z (S) $2500.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306807975.