ELKTON, VA —
OSHA Inspection: COORS BREWING COMPANY
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of COORS BREWING COMPANY in RT. 340, ELKTON, VA 22827 (NAICS 312120). OSHA activity number 306816109.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COORS BREWING COMPANY
- Site address
- RT. 340
- City
- ELKTON
- State
- VA
- ZIP
- 22827
- Mailing
- P. O. BOX 25, ELKTON, VA 22827
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 312120
- SIC code (legacy)
- 2082
- Employees
- 250
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
2 citations on file for this inspection.
510001 A
- Issued
- Mar 5, 2004
- Abate by
- Mar 9, 2004
- Penalty
- Initial $975 · Current $975
General-duty citation text
40.1-51.1(a) of the Code of Virginia: The employer, Coors Brewing Company, did not furnish a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm in that employees were exposed to fire and explosion hazards while working on or around sludge storage tanks. Inspections and routine maintenance had not been performed according to manufacturers recommendations. Inspections and maintenance had not been performed on the Shand & Jurs Flame Arrester, Model 94306 and the Shand & Jurs Pressure/Vacuum Breather Valve, Model 94020 which were located on top of a 440,000 gallon sludge storage tank at the Waste Water Treatment Facility at Coors Brewing Company, Rt. 340, Elkton, VA. The flame arrester acts as a end of line fire barrier between flammable liquids stored in low pressure tanks and its emitted combustible vapors. It provides a positive flame stop for flammable liquids. One feasible and acceptable abatement method, among other methods, to correct this hazard would be to inspect the bank of the flame arrester at least once a month for the first year after installation and clean the tube bank whenever the inspection shows the need as recommended by the Instruction Manual for the Shand & Jurs Flame Arrester. These inspections and the frequency of cleaning will provide the basis to establish a predetermine maintenance program. The Instruction Manual for the Shand & Jurs Pressure/Vacuum Breather Valve recommends inspection and maintenance a minimum once every three months.
Recent events (2)
- — Y (S) $975.00
- — Z (S) $975.00
1926.352 I
- Issued
- Mar 5, 2004
- Abate by
- Mar 10, 2004
- Penalty
- Initial $70,000 · Current $70,000
Recent events (2)
- — Y (U) $70000.00
- — Z (W) $70000.00
More inspections at Coors Brewing Company
View Coors Brewing Company's full OSHA safety record →
More inspections in this industry (NAICS 312120)
More inspections in VA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306816109.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.