LIBERTYVILLE, IL —
OSHA Inspection: ZELLER PLASTIK,INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ZELLER PLASTIK,INC. in 1515 FRANKLIN BLVD, LIBERTYVILLE, IL 60048 (NAICS 326199). OSHA activity number 306895228.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ZELLER PLASTIK,INC.
- Site address
- 1515 FRANKLIN BLVD
- City
- LIBERTYVILLE
- State
- IL
- ZIP
- 60048
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 326199
- SIC code (legacy)
- 3089
- Employees
- 187
- Ownership type
- A
Citations
4 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 29, 2003
- Abate by
- Sep 25, 2003
- Penalty
- Initial $1,125 · Current $787 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the rotating blade: a)Tool Room-The Roll-IN vertical band saw serial# EF1459, was not equipped with magnetic restarter or similar device, as prescribed by American National Standards Institute (ANSI) B11.10-1990, Section 5.2.3.4, that in the event of an interruption in the electrical supply such a device would prevent the saw from restarting automatically when power is restored. b)Tool Room-The Baldor Chop saw serial#35P355560, was not equipped with a magnetic restarter or similar device, as prescribed by American National Standards Institute (ANSI) B11.10-1990, section 5.2.3.4, that in the event of an interuption in electrical supply such a device would prevent the saw from restarting automatically when power is restored. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).s
Recent events (2)
- — I (S) $787.00
- — Z (S) $1125.00
1910.212 A01
- Issued
- Aug 29, 2003
- Abate by
- Sep 25, 2003
- Penalty
- Initial $3,500 · Current $2,450 Reduced
Recent events (2)
- — I (S) $2450.00
- — Z (S) $3500.00
1910.219 D01
- Issued
- Aug 29, 2003
- Abate by
- Sep 25, 2003
- Penalty
- Initial $900 · Current $630 Reduced
Recent events (2)
- — I (S) $630.00
- — Z (S) $900.00
1910.219 E03 I
- Issued
- Aug 29, 2003
- Abate by
- Sep 25, 2003
Recent events (2)
- — I (S)
- — Z (S)
More inspections at Zeller Plastik,Inc.
View Zeller Plastik,Inc.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 306895228.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.